A does not do anything, that is external mobile. Our app uses REFER to get from B to C, then a redirect (INVITE) to get from C to D. When A hangs up, the call does not drop because sipXBridge ignores the BYE.
I attached merged.xml, is there some other trace you are asking for Dale? Sven -----Original Message----- From: Dale Worley [mailto:[email protected]] Sent: 06 February 2010 14:15 To: Sven Evensen Cc: [email protected] Subject: Re: [sipx-users] sipXbridge ignoring a BYE On Sat, 2010-02-06 at 13:22 +0000, Sven Evensen wrote: > A Mobile 07795951717 > > B Internal phantom user 8116 > > C Internal phantom user 8216 > > D Mobile 07791788997 > > > > B calls A, A answers > > B transferred to C > > C transferred to D > > A hangs up before D answers When you say "B transferred to C", do you mean that A transfers the call to C? And what sort of transfer is it, a "blind" transfer, where A does not wait for C to answer, or a "consultative" transfer, where A first establishes a new connection to C, and then causes B to be connected to C? It would help a great deal if you could extract a call trace of all the dialogs involved. Dale * _______________________________________________ sipx-users mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-users Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users sipXecs IP PBX -- http://www.sipfoundry.org/