http://www-europe.cisco.com/en/US/products/ps10024/products_qanda_item09186a0080a359cc.shtml

-Eric

On Feb 18, 2010, at 6:35 PM, warner steven wrote:

> 
> Do you possibly have a pointer to that doc?
> 
> s
> 
> On Feb 18, 2010, at 12:16 PM, Eric Varsanyi wrote:
> 
>> I had echo issues with the defaults but tweaking the gain settings per a FAQ 
>> on Linksys's site fixed them and the audio quality was acceptable (the 
>> analog POTS lines I've connected to aren't themselves all that great so this 
>> isn't saying too much).
>> 
>> On these same lines an Audiocodes 4x4 sounded about the same to me after 
>> tweaking (using a Polycom 650 to make/receive calls). The Patton I have now 
>> in this role sounds about the same too, I guess I'm not an audiophile :)
>> 
>> -Eric Varsanyi
>> 
>> On Feb 18, 2010, at 12:35 PM, warner steven wrote:
>> 
>>> 
>>> I have gotten the SPA3102 running for In and Out.  I can
>>> help with settings if anyone really wants it.
>>> 
>>> But this device has horrible echo cancellation problems.
>>> 
>>> I finally gave up and with with AudioCodes, which is has much
>>> higher audio quality.
>>> 
>>> s
>>> 
>>>>>>> 
>>>>>>> 
>>>>> 
>>>>>> I'm trying to configure a spa3102 for outbound calls only. I know people 
>>>>>> pull their hair out over these devices, but I wanted to give it a shot. 
>>>>>> My only gateways I've worked with so far are sipxbridge and an 
>>>>>> audiocodes configred from within sipx, so I haven't really done too much 
>>>>>> manual FXO configuration.
>>>>>> I think I may be missing something on the sipx end, because I don't 
>>>>>> think the call is ever making it to the spa3102. This is a new setup and 
>>>>>> has no other gateways. I added the spa3102 as an unmanaged gateway. I 
>>>>>> enabled all the dialing plans and added the gateway. I'm using a polycom 
>>>>>> 550, Sipx 4.0.4,  bootrom 4.2.1, firmware 3.1.3C split. I would show a 
>>>>>> siptrace, but the merged file doesn't really have anything in it. The 
>>>>>> sipx server is at 10.81.1.5. The spa3102 is at 10.81.1.6. I tried 
>>>>>> setting the gateway in sipx to UDP manually (that is what the spa3102 
>>>>>> defaults to) and specifying port 5060, but that didn't seem to change 
>>>>>> anything. There are only 2 logs created, so I attached those. Is there 
>>>>>> something simple I'm missing? I read through this, 
>>>>>> http://sipx-wiki.calivia.com/index.php/HowTo_configure_sipX_to_work_with_FXO/FXS_SIP_Gateways
>>>>>>  but I don't see anything that sticks out at me. The only thig I thought 
>>>>>> I might need to do is something in authrules.xml, but I'm still 
 not
>>> sure since the text around it refers to FXS and this is FXO. I sort of 
>>> guess there has to be some some sort of authorization for the spa3102 to 
>>> know the sipx call can be sent outbound, but I don't know where to do this. 
>>> Sorry if I'm missing something obvious here. I think the fact that I got an 
>>> audiocodes 8 port working inbound and outbound with no questions (and 
>>> clearly not much knowledge on the subject) is a testament to how well sipx 
>>> is able to configure it!
>>> 
>>> _______________________________________________
>>> sipx-users mailing list [email protected]
>>> List Archive: http://list.sipfoundry.org/archive/sipx-users
>>> Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users
>>> sipXecs IP PBX -- http://www.sipfoundry.org/
>> 
> 

_______________________________________________
sipx-users mailing list [email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users
Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users
sipXecs IP PBX -- http://www.sipfoundry.org/

Reply via email to