Its s remote endpoint...DO you mean the endpoint shud be in th same network as SipX?
From: [email protected] [mailto:[email protected]] On Behalf Of Michael Scheidell Sent: Saturday, August 14, 2010 2:36 PM To: [email protected] Subject: Re: [sipx-users] Inbound call from ITSP to registered Extension - No AUdio On 8/14/10 2:57 PM, Ujjval Karihaloo wrote: sipXconfig (4.2.1-018930 2010-06-04T15:25:27 build34) I have a User defined...but no Phone Type as I am registering a Softphone Eyebeam which is not in the list of Phone devices.... There is 1 Regsitration as shown below SipX"<sip:[email protected]><sip:[email protected]> <sip:[email protected]:21979;rinstance=4940c5557ff9e0cc;x-sipX-privcontact=174.51.210.xxx%3A21979><sip:[email protected]:21979;rinstance=4940c5557ff9e0cc;x-sipX-privcontact=174.51.210.xxx%3A21979> 179 privcontact needs to be an internal address. you are using the public (global) address? it should be the internal ip. -- Michael Scheidell, CTO o: 561-999-5000 d: 561-948-2259 ISN: 1259*1300 > | SECNAP Network Security Corporation * Certified SNORT Integrator * 2008-9 Hot Company Award Winner, World Executive Alliance * Five-Star Partner Program 2009, VARBusiness * Best in Email Security,2010: Network Products Guide * King of Spam Filters, SC Magazine 2008 ________________________________ This email has been scanned and certified safe by SpammerTrap(r). For Information please see http://www.secnap.com/products/spammertrap/ ________________________________