On 10/7/10 3:12 PM, Roman Gelfand wrote:
If I am not mistaken, I have to publish ports 5080/udp and
30000-31000/tcp on the wan.
5060, udp/tcp if you support inbound sip: url calls and/or remote users.
5080/udp/tcp for ITSP's
30000-31000 UDP.
note: turn off all sip helpers, alg, etc.
you MUST USE 1:1 STATIC NATTING or you get one sided voice calls, if
anything.
there are a LOT of FAQ's on this, so, wherever you got 30000-31000 tcp,
ignore it, blacklist it, don't listen to anything it says.
Is that correct?