Anyone? J
From: [email protected] [mailto:[email protected]] On Behalf Of Henry Dogger Sent: donderdag 16 juni 2011 11:53 To: Discussion list for users of sipXecs software Subject: [sipx-users] difference in pickup from mediant gateway Hi all, Currently we are testing tiptel phones to see if they support the features we would like to have, as an alternative to polycom. Perhaps someone already tested these phones and could provide some info J The issue I see atm is when trying to pickup a call coming in on a tiptel phone from a mediant gateway using call pickup (*78), this fails. Every other call pickup works properly.... I tried this as well with a call arriving on a polycom, and this works. I made two traces one from polycom and one from the tiptel phone (also attached these) What I noticed as a difference is the "302 moved temporarily" message from the registrar back to the proxy. When the call is arriving on the polycom it returns the 302 message with a contact header: [email protected] (which is the correct ip of the gateway) When the call is arriving on the tiptel however the 302 message contains a contact header: [email protected] (which is the domain of my system) Is the phone causing this difference, or is it somewhere done in sipXecs? I can only fix this issue to change the setting "Gateway Name" (in Proxy and Registration tab of gateway) from domain to IP address... Kind regards, Henry Dogger Telecats BV
_______________________________________________ sipx-users mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-users/