Hi Todd,

I too have multiple ITSP's configured.  Two to voip.ms (each to a different
point of presence) and one to an ITSP in Switzerland.

The static NAT may be an issue as Tony stated.  (only so many machines can
come and go on 5060 or 5080 at the same time...  and that number = 1).

What I find I have to do is static NAT only the sipXecs server and not the
phones.  This will allow the traffic to/from the server to come and go on
the necessary ports but then phones can use whatever ports they might need.

Mike

On Fri, Nov 11, 2011 at 5:06 PM, Todd Hodgen <[email protected]> wrote:

> I have an account that currently has one ITSP running under sipxbridge.
> I’m adding a second one, completely different company, IP, etc.
> Unfortunately, when I added it, the current ITSP failed, and neither ITSP
> shows up as trying to register under the diagnostics tab.  In fact, under
> that tab, there is nothing attempting anything.****
>
> ** **
>
> I know this works, and have done it many times.   This particular server
> is running 4.4.  Has anyone experienced an issue with 4.4 with trying to
> run multiple ITSP’s.  I’ll troubleshoot this further next week, but wanted
> to ferret out if anyone has seen this issue in the past before spending a
> lot of fruitless time.****
>
> _______________________________________________
> sipx-users mailing list
> [email protected]
> List Archive: http://list.sipfoundry.org/archive/sipx-users/
>



-- 
Michael Picher, Director of Technical Services
eZuce, Inc.

300 Brickstone Square****

Suite 201****

Andover, MA. 01810
O.978-296-1005 X2015
M.207-956-0262
@mpicher <http://twitter.com/mpicher>
www.ezuce.com
_______________________________________________
sipx-users mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users/

Reply via email to