ewww...

very easy to punch holes in it..., digit map is bypassed on polycom if you
dial on-hook....

mike

On Wed, Jan 25, 2012 at 10:54 AM, Todd Hodgen <[email protected]> wrote:

> One very limited option you might consider is with the dial strings in the
> devices.  For example, if you limit strings from being dials, something
> like |2xxx|[4-9]xxx| should disallow the dialing of 3xxx numbers.****
>
> ** **
>
> Not that this would be pretty, but I’ve used similar to control access to
> a range of extensions.   This could get ugly fast, and I suspect easy to
> punch holes in it.****
>
> ** **
>
> *From:* [email protected] [mailto:
> [email protected]] *On Behalf Of *Michael Picher
> *Sent:* Wednesday, January 25, 2012 2:51 AM
> *To:* Discussion list for users of sipXecs software
> *Subject:* Re: [sipx-users] Disallowing site-to-site calls****
>
> ** **
>
> Well, this isn't a tenanted system, so that's first and foremost.****
>
> ** **
>
> Since user extensions and user aliases are processed before dial plan
> entries, there's no way to prevent this.****
>
> ** **
>
> User permissions secure an entire dial plan entry.****
>
> ** **
>
> Locations (or branches) secure gateways inside a dial plan entry.****
>
> ** **
>
> There's no way on a single system to prevent user 2050 from calling user
> 3050.****
>
> ** **
>
> Mike****
>
> On Wed, Jan 25, 2012 at 2:51 AM, Paul Kramer <[email protected]>
> wrote:****
>
> Hello, I was wondering if anyone knows how to segment sites in a way that
> will disallow all users from a given site to make calls to all users from
> other sites. This question has surfaced due to a multi-tenanting query from
> a customer.
> _______________________________________________
> sipx-users mailing list
> [email protected]
> List Archive: http://list.sipfoundry.org/archive/sipx-users/****
>
>
>
> ****
>
> ** **
>
> --
> Michael Picher, Director of Technical Services
> eZuce, Inc.****
>
> 300 Brickstone Square****
>
> Suite 201****
>
> Andover, MA. 01810****
>
> O.978-296-1005 X2015
> M.207-956-0262
> @mpicher <http://twitter.com/mpicher>
> www.ezuce.com****
>
> ** **
>
>
> ------------------------------------------------------------------------------------------------------------
> ****
>
> Hope to see you at the sipX CoLab! http://www.sipfoundry.org/sipx-colab***
> *
>
> A gathering for - open source users, eZuce customers & eZuce partners****
>
> Get the inside track on 4.6 and a glimpse at the future of sipXecs!****
>
> ** **
>
> _______________________________________________
> sipx-users mailing list
> [email protected]
> List Archive: http://list.sipfoundry.org/archive/sipx-users/
>



-- 
Michael Picher, Director of Technical Services
eZuce, Inc.

300 Brickstone Square****

Suite 201****

Andover, MA. 01810
O.978-296-1005 X2015
M.207-956-0262
@mpicher <http://twitter.com/mpicher>
www.ezuce.com

------------------------------------------------------------------------------------------------------------
Hope to see you at the sipX CoLab! http://www.sipfoundry.org/sipx-colab
A gathering for - open source users, eZuce customers & eZuce partners
Get the inside track on 4.6 and a glimpse at the future of sipXecs!
_______________________________________________
sipx-users mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users/

Reply via email to