Downgrade to 8.2 version - It will work.8.3 onwards - Security prevents calling Polycom<>Cisco Date: Sun, 20 May 2012 06:09:24 -0400 From: [email protected] To: [email protected] Subject: Re: [sipx-users] Polycom calling Cisco issue (XX-8762)
Yea the actual problems turned out to be much deeper than this... such as they cisco phones won't take calls from servers they aren't registered to (this is why single server installs worked but HA systems tended to fail). There are still a couple other issues we're trying to work through for a customer who would like to keep a few thousand of these phones... Mike On Sun, May 20, 2012 at 12:58 AM, Becker, Jesse <[email protected]> wrote: Josh, This issue is why Sen and I gave up on the interop of the Cisco Plus profiles in 2009. Sen and i put in a lot if effort to getting the 7906 and 79x1 series phones to fully work with SipX. The latest patch allowed full provisioning, however we found that each version of the Cisco SIP firmware had different issues. The earlier versions had issues with transferring and the message waiting light. The later versions still had issues with blind transfers, however, MWI worked. We thought we were moving forward, however later discovered the issue that cisco and polycoms were no longer able to call each other. That's when I called it quits and stopped trying to make it work. On May 5, 2012 12:12 AM, "Josh Patten" <[email protected]> wrote: For those of you who have mixed Cisco/Polycom environments and want to call from Polycom to Cisco, here is a temp workaround until something better can be devised: http://track.sipfoundry.org/browse/XX-8762 -- Josh Patten eZuce Solutions Architect O.978-296-1005 X2050 M.979-574-5699 http://www.ezuce.com _______________________________________________ sipx-users mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-users/ _______________________________________________ sipx-users mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-users/ -- Michael Picher, Director of Technical Services eZuce, Inc. 300 Brickstone Square Suite 201Andover, MA. 01810O.978-296-1005 X2015 M.207-956-0262 @mpicher <http://twitter.com/mpicher> www.ezuce.com ------------------------------------------------------------------------------------------------------------ There are 10 kinds of people in the world, those who understand binary and those who don't. _______________________________________________ sipx-users mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-users/
_______________________________________________ sipx-users mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-users/