I reinstalled my sipx according to your setup. 201 is registered on primary server(with ip address in domain, 92.168.0.46)
200 is registered on secondary server(with ip address in domain, 192.168.0.47) 201 to 200 works normaly 200 to 201 gives error "user is temporarily unavailable(404)" 200 to [email protected](primary server ip address) works https://www.dropbox.com/s/cn9vqmt25zurm2z/sipx-snapshot-sipx1.callidus.local .tar.gz https://www.dropbox.com/s/loqjb4v0x74kktm/sipx-snapshot-sipx2.callidus.local .tar.gz -----Original Message----- From: [email protected] [mailto:[email protected]] On Behalf Of George Niculae Sent: Friday, September 28, 2012 5:47 PM To: Discussion list for users of sipXecs software Subject: Re: [sipx-users] 4.6 Cluster On Fri, Sep 28, 2012 at 4:35 PM, darthzejdr <[email protected]> wrote: > Didnt help. Everything the same. If i try to call extension on second > server i get The user is temporarily unavailable (404 ) > That's what I did, let me know if testing scenario different: - setup cluster with 2 nodes, both running DNS, Proxy and Registrar - configured secondary IP and fqdn as domain aliases, then sent profiles to servers - registered account 200 Bria on first node (giving 1st node IP as domain) - registered account 201, another phone on 2nd node (giving 2nd node IP as domain) - calls 200 to 200 established just fine George _______________________________________________ sipx-users mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-users/
_______________________________________________ sipx-users mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-users/
