The short answer is, since FreeSWITCH is authoritative (A registrar by itself), It will not pass through the registrations to sipx nor would it passthrough challenge responses (401 and 407). This would limit you to use FreeSWITCH only as a sip trunk (unmanaged) gateway.
On 01/10/2013 07:01 AM, Alan Worstell wrote: > Hello, > Since it appears the feature to have the sipXbridge accept ITSP > signaling on port 5060 didn't make it in to this release, I am looking > in to setting up a Freeswitch SBC to handle the ITSP traffic. Since I > also require the remote worker functionality, would I then have to have > two separate public IP addresses for the SBC and the sipx server, or can > the SBC pass through the remote SIP registration to the proxy? What is > recommended for this type of setup? > > Thanks, > _______________________________________________ sipx-users mailing list [email protected] List Archive: http://list.sipfoundry.org/archive/sipx-users/