Hi Colin,
The Blue LED continuously flashing means, then there is no association with any AP. The instability issue is due to RF interference and environmental related
The BETA firmware 0.01.08 is useful where there is periodic disassociation after long period of operation which requires power cycle or software reset the unit in order to re-associate. This firmware may not be able re-associate if the signal strength is less than 50%. In order to avoid any disassociation due to certain conditions, the CPE should maintain the LQ & RSSI values not less than 75%.
If you are interested to try, please let us know so that I can send it to your off list.
Thank you
-----Original Message-----
We have a number of ABO's operating, but recently some of them have been experiencing wierd lockups - The unit will totally lockup, all the lights are on, the 'Blue LED' is constantly flashing (in search mode?). If I power cycle the unit this fixes the problem, but it appears to be occuring more and more - i.e. once a unit has started doing it - it doesn't stop. Now all our units use 00.01.07 firmware - I realise 00.01.08 is in 'beta' - does this address this particular issue? All I want is a quiet life - install it and then never hear from the customer again ;), and it's been like that for ages, just recently this spate of association issues.
Many Thanks
Colin. |
- [smartBridges] Linking the Mt. Everest Nimesh D. Parikh
- [smartBridges] ABO Goes Dead Colin Watson
- Re: [smartBridges] ABO Goes Dead Blazen Wireless
- Seeni Mohamed