Hello,

Third and last for today :-)

command : /root/smartctl-5.38 -a -d ata /dev/sda -T permissive

Thanks.

Gerald

----- Command result  follow

smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Model Family:     Hitachi Deskstar 7K1000
Device Model:     Hitachi HDS721075KLA330
Serial Number:    GTA200P8G0NY8A
Firmware Version: GK8OA70M
User Capacity:    750,156,374,016 bytes
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   7
ATA Standard is:  ATA/ATAPI-7 T13 1532D revision 1
Local Time is:    Wed Oct  1 12:18:47 2008 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x85) Offline data collection activity
                                         was aborted by an interrupting
command from host.
                                         Auto Offline Data Collection:
Enabled.
Self-test execution status:      (   0) The previous self-test routine
completed
                                         without error or no self-test
has ever
                                         been run.
Total time to complete Offline
data collection:                 (11471) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                         Auto Offline data collection
on/off support.
                                         Suspend Offline collection upon new
                                         command.
                                         Offline surface scan supported.
                                         Self-test supported.
                                         No Conveyance Self-test supported.
                                         Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                         power-saving mode.
                                         Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                         General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 191) minutes.
SCT capabilities:              (0x003f) SCT Status supported.
                                         SCT Feature Control supported.
                                         SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE
UPDATED  WHEN_FAILED RAW_VALUE
   1 Raw_Read_Error_Rate     0x000b   100   100   016    Pre-fail
Always       -       0
   2 Throughput_Performance  0x0005   130   130   054    Pre-fail
Offline      -       152
   3 Spin_Up_Time            0x0007   163   163   024    Pre-fail
Always       -       365 (Average 369)
   4 Start_Stop_Count        0x0012   100   100   000    Old_age
Always       -       13
   5 Reallocated_Sector_Ct   0x0033   100   100   005    Pre-fail
Always       -       0
   7 Seek_Error_Rate         0x000b   100   100   067    Pre-fail
Always       -       0
   8 Seek_Time_Performance   0x0005   136   136   020    Pre-fail
Offline      -       31
   9 Power_On_Hours          0x0012   099   099   000    Old_age
Always       -       10087
  10 Spin_Retry_Count        0x0013   100   100   060    Pre-fail
Always       -       0
  12 Power_Cycle_Count       0x0032   100   100   000    Old_age
Always       -       13
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always
       -       371
193 Load_Cycle_Count        0x0012   100   100   000    Old_age   Always
       -       371
194 Temperature_Celsius     0x0002   100   100   000    Old_age   Always
       -       60 (Lifetime Min/Max 23/68)
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always
       -       0
197 Current_Pending_Sector  0x0022   100   100   000    Old_age   Always
       -       0
198 Offline_Uncorrectable   0x0008   100   100   000    Old_age
Offline      -       0
199 UDMA_CRC_Error_Count    0x000a   200   200   000    Old_age   Always
       -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining
LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed without error       00%     10086
      -
# 2  Short offline       Completed without error       00%      8573
      -

SMART Selective self-test log data structure revision number 1
  SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
     1        0        0  Not_testing
     2        0        0  Not_testing
     3        0        0  Not_testing
     4        0        0  Not_testing
     5        0        0  Not_testing
Selective self-test flags (0x0):
   After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.



-- 
ASTREL "Raison & Télécom"
14 rue du perigord
69330 Meyzieu
[EMAIL PROTECTED] - http://www.astrel.fr
Tel: (+33/0) 4 72 45 08 16
Fax: (+33/0) 4 72 45 08 19




-------------------------------------------------------------------------
This SF.Net email is sponsored by the Moblin Your Move Developer's challenge
Build the coolest Linux based applications with Moblin SDK & win great prizes
Grand prize is a trip for two to an Open Source event anywhere in the world
http://moblin-contest.org/redirect.php?banner_id=100&url=/
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to