Hi, I see the current CVS version smartmontools does not yet include the Seagate Momentus 5400.5 series of drives in its database.
Page about the Seagate Momentus 5400.5 series drives http://www.seagate.com/www/en-us/products/laptops/momentus/momentus_5400.5/ Model numbers are: Capacity Model # 80GB ST980310AS 120GB ST9120310AS 160GB ST9160310AS 250GB ST9250320AS 320GB ST9320320AS Please find the following attached: 1) smartctl -a output for my 160GB ST9160310AS drive, 2) patch to add Seagate Momentus 5400.5 series to known drives. Thanks, Mike Fleetwood
smartctl 5.39 2009-04-28 21:11 [i686-pc-linux-gnu] (local build) Copyright (C) 2002-9 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Device Model: ST9160310AS Serial Number: 5SV4SS27 Firmware Version: 0303 User Capacity: 160,041,885,696 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 4 Local Time is: Sun May 3 11:47:13 2009 BST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 712) seconds. Offline data collection capabilities: (0x73) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 58) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x103f) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 116 100 006 Pre-fail Always - 106266246 3 Spin_Up_Time 0x0003 099 099 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 51 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 100 253 030 Pre-fail Always - 213323 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 166 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 51 184 Unknown_Attribute 0x0032 100 100 099 Old_age Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 188 Unknown_Attribute 0x0032 100 099 000 Old_age Always - 22 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 057 054 045 Old_age Always - 43 (Lifetime Min/Max 17/46) 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 8 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 5 193 Load_Cycle_Count 0x0032 093 093 000 Old_age Always - 15479 194 Temperature_Celsius 0x0022 043 046 000 Old_age Always - 43 (0 17 0 0) 195 Hardware_ECC_Recovered 0x001a 051 050 000 Old_age Always - 106266246 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 165 - # 2 Extended offline Completed without error 00% 153 - # 3 Short offline Completed without error 00% 151 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.
smartmontools_Seagate_Momentus_5400_5.patch
Description: Binary data
------------------------------------------------------------------------------ Register Now & Save for Velocity, the Web Performance & Operations Conference from O'Reilly Media. Velocity features a full day of expert-led, hands-on workshops and two days of sessions from industry leaders in dedicated Performance & Operations tracks. Use code vel09scf and Save an extra 15% before 5/3. http://p.sf.net/sfu/velocityconf
_______________________________________________ Smartmontools-database mailing list Smartmontools-database@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/smartmontools-database