Hi,
this is Western Digital 250GB SATAII RAID series.
I have mirror setup, so sends output of both disks.
--
Witold Baryluk
smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: WDC WD2502ABYS-01B7A0
Serial Number: WD-WCAT1A257695
Firmware Version: 02.03B02
User Capacity: 251,059,544,064 bytes
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 8
ATA Standard is: Exact ATA specification draft version not indicated
Local Time is: Tue Jun 16 20:01:22 2009 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x85) Offline data collection activity
was aborted by an interrupting command
from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (4800) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 59) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x303f) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always
- 0
3 Spin_Up_Time 0x0027 201 200 021 Pre-fail Always
- 916
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always
- 24
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always
- 0
7 Seek_Error_Rate 0x002e 100 253 000 Old_age Always
- 0
9 Power_On_Hours 0x0032 100 100 000 Old_age Always
- 505
10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always
- 0
11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always
- 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always
- 22
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always
- 18
193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always
- 24
194 Temperature_Celsius 0x0022 106 105 000 Old_age Always
- 37
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always
- 0
197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always
- 0
198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline
- 0
199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always
- 0
200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline
- 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 488 -
# 2 Short offline Completed without error 00% 464 -
# 3 Short offline Completed without error 00% 440 -
# 4 Extended offline Completed without error 00% 418 -
# 5 Short offline Completed without error 00% 416 -
# 6 Short offline Completed without error 00% 392 -
# 7 Short offline Completed without error 00% 368 -
# 8 Short offline Completed without error 00% 344 -
# 9 Short offline Completed without error 00% 320 -
#10 Short offline Completed without error 00% 296 -
#11 Short offline Completed without error 00% 272 -
#12 Extended offline Completed without error 00% 250 -
#13 Short offline Completed without error 00% 248 -
#14 Short offline Completed without error 00% 224 -
#15 Short offline Completed without error 00% 201 -
#16 Short offline Completed without error 00% 177 -
#17 Short offline Completed without error 00% 153 -
#18 Short offline Completed without error 00% 129 -
#19 Short offline Completed without error 00% 105 -
#20 Extended offline Completed without error 00% 83 -
#21 Short offline Completed without error 00% 81 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: WDC WD2502ABYS-01B7A0
Serial Number: WD-WCAT1A833632
Firmware Version: 02.03B02
User Capacity: 251,059,544,064 bytes
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 8
ATA Standard is: Exact ATA specification draft version not indicated
Local Time is: Tue Jun 16 20:04:23 2009 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x80) Offline data collection activity
was never started.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (4800) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 59) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x303f) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 100 253 051 Pre-fail Always
- 0
3 Spin_Up_Time 0x0027 201 201 021 Pre-fail Always
- 925
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always
- 6
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always
- 0
7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always
- 0
9 Power_On_Hours 0x0032 100 100 000 Old_age Always
- 50
10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always
- 0
11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always
- 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always
- 4
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always
- 3
193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always
- 6
194 Temperature_Celsius 0x0022 094 093 000 Old_age Always
- 49
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always
- 0
197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always
- 0
198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline
- 0
199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always
- 0
200 Multi_Zone_Error_Rate 0x0008 100 253 000 Old_age Offline
- 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
Crystal Reports - New Free Runtime and 30 Day Trial
Check out the new simplified licensing option that enables unlimited
royalty-free distribution of the report engine for externally facing
server and web deployment.
http://p.sf.net/sfu/businessobjects
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database