smartctl -a /dev/sda
smartctl 5.39 2008-10-24 22:33 [x86_64-suse-linux-gnu] (openSUSE RPM)
Copyright (C) 2002-8 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     MARVELL SD88SA024BA0 SUN24G 0902M0054V
Serial Number:    0902M0054V
Firmware Version: 1209T49M
User Capacity:    24,575,868,928 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   7
ATA Standard is:  ATA/ATAPI-7 T13 1532D revision 4a
Local Time is:    Wed Jul 15 10:06:17 2009 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

Error SMART Thresholds Read failed: Input/output error
Smartctl: SMART Read Thresholds failed.

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Total time to complete Offline 
data collection:                 (   0) seconds.
Offline data collection
capabilities:                    (0x00)         Offline data collection not 
supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x00) Error logging NOT supported.
                                        No General Purpose Logging support.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  2 Throughput_Performance  0x2600   000   000   000    Old_age   Offline  
FAILING_NOW 281474959933440
  2 Throughput_Performance  <== Data Page      |  WARNING: PREVIOUS ATTRIBUTE 
HAS TWO
  0 Unknown_Attribute       <== Threshold Page |  INCONSISTENT IDENTITIES IN 
THE DATA
 12 Power_Cycle_Count       0x30fe   000   014   000    Old_age   Always   
FAILING_NOW 281474959933440
 12 Power_Cycle_Count       <== Data Page      |  WARNING: PREVIOUS ATTRIBUTE 
HAS TWO
  0 Unknown_Attribute       <== Threshold Page |  INCONSISTENT IDENTITIES IN 
THE DATA
192 Power-Off_Retract_Count 0x30fe   000   013   000    Old_age   Always   
FAILING_NOW 281474959933440
192 Power-Off_Retract_Count <== Data Page      |  WARNING: PREVIOUS ATTRIBUTE 
HAS TWO
  0 Unknown_Attribute       <== Threshold Page |  INCONSISTENT IDENTITIES IN 
THE DATA
196 Reallocated_Event_Count 0x30fe   000   000   000    Old_age   Always   
FAILING_NOW 0 (65535, 65280)
196 Reallocated_Event_Count <== Data Page      |  WARNING: PREVIOUS ATTRIBUTE 
HAS TWO
  0 Unknown_Attribute       <== Threshold Page |  INCONSISTENT IDENTITIES IN 
THE DATA
210 Unknown_Attribute       0x3300   000   000   000    Old_age   Offline  
FAILING_NOW 281474959933440
210 Unknown_Attribute       <== Data Page      |  WARNING: PREVIOUS ATTRIBUTE 
HAS TWO
  0 Unknown_Attribute       <== Threshold Page |  INCONSISTENT IDENTITIES IN 
THE DATA
211 Unknown_Attribute       0x3300   000   000   000    Old_age   Offline  
FAILING_NOW 281474959933440
211 Unknown_Attribute       <== Data Page      |  WARNING: PREVIOUS ATTRIBUTE 
HAS TWO
  0 Unknown_Attribute       <== Threshold Page |  INCONSISTENT IDENTITIES IN 
THE DATA
212 Unknown_Attribute       0x3100   000   076   000    Old_age   Offline  
FAILING_NOW 281474959933440
212 Unknown_Attribute       <== Data Page      |  WARNING: PREVIOUS ATTRIBUTE 
HAS TWO
  0 Unknown_Attribute       <== Threshold Page |  INCONSISTENT IDENTITIES IN 
THE DATA
213 Unknown_Attribute       0x3100   000   000   000    Old_age   Offline  
FAILING_NOW 281474959933440
213 Unknown_Attribute       <== Data Page      |  WARNING: PREVIOUS ATTRIBUTE 
HAS TWO
  0 Unknown_Attribute       <== Threshold Page |  INCONSISTENT IDENTITIES IN 
THE DATA

Warning: device does not support Error Logging
Error SMART Error Log Read failed: Input/output error
Smartctl: SMART Error Log Read Failed
Warning: device does not support Self Test Logging
Error SMART Error Self-Test Log Read failed: Input/output error
Smartctl: SMART Self Test Log Read Failed
Device does not support Selective Self Tests/Logging

------------------------------------------------------------------------------
Enter the BlackBerry Developer Challenge  
This is your chance to win up to $100,000 in prizes! For a limited time, 
vendors submitting new applications to BlackBerry App World(TM) will have
the opportunity to enter the BlackBerry Developer Challenge. See full prize  
details at: http://p.sf.net/sfu/Challenge
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to