Sun Microsystems GmbH Marcel Kau
Brandenburgerstr. 2 Consultant High-End Server (SDO)
40880 Ratingen Tel. +49 (0)2102-4511-794
Germany Fax: +49 (0)2102-4511-672
http://www.sun.de mailto:marcel....@sun.com
********************************************************************************
Sitz der Gesellschaft:
Sun Microsystems GmbH, Sonnenallee 1, D-85551 Kirchheim-Heimstetten
Amtsgericht Muenchen: HRB 161028
Geschaeftsfuehrer: Thomas Schroeder, Wolfgang Engels, Wolf Frenkel
Vorsitzender des Aufsichtsrates: Martin Haering
smartctl -a /dev/sda
smartctl 5.39 2008-10-24 22:33 [x86_64-suse-linux-gnu] (openSUSE RPM)
Copyright (C) 2002-8 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Device Model: MARVELL SD88SA024BA0 SUN24G 0902M0054V
Serial Number: 0902M0054V
Firmware Version: 1209T49M
User Capacity: 24,575,868,928 bytes
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 7
ATA Standard is: ATA/ATAPI-7 T13 1532D revision 4a
Local Time is: Wed Jul 15 10:06:17 2009 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
Error SMART Thresholds Read failed: Input/output error
Smartctl: SMART Read Thresholds failed.
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x00) Offline data collection not
supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x00) Error logging NOT supported.
No General Purpose Logging support.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
2 Throughput_Performance 0x2600 000 000 000 Old_age Offline
FAILING_NOW 281474959933440
2 Throughput_Performance <== Data Page | WARNING: PREVIOUS ATTRIBUTE
HAS TWO
0 Unknown_Attribute <== Threshold Page | INCONSISTENT IDENTITIES IN
THE DATA
12 Power_Cycle_Count 0x30fe 000 014 000 Old_age Always
FAILING_NOW 281474959933440
12 Power_Cycle_Count <== Data Page | WARNING: PREVIOUS ATTRIBUTE
HAS TWO
0 Unknown_Attribute <== Threshold Page | INCONSISTENT IDENTITIES IN
THE DATA
192 Power-Off_Retract_Count 0x30fe 000 013 000 Old_age Always
FAILING_NOW 281474959933440
192 Power-Off_Retract_Count <== Data Page | WARNING: PREVIOUS ATTRIBUTE
HAS TWO
0 Unknown_Attribute <== Threshold Page | INCONSISTENT IDENTITIES IN
THE DATA
196 Reallocated_Event_Count 0x30fe 000 000 000 Old_age Always
FAILING_NOW 0 (65535, 65280)
196 Reallocated_Event_Count <== Data Page | WARNING: PREVIOUS ATTRIBUTE
HAS TWO
0 Unknown_Attribute <== Threshold Page | INCONSISTENT IDENTITIES IN
THE DATA
210 Unknown_Attribute 0x3300 000 000 000 Old_age Offline
FAILING_NOW 281474959933440
210 Unknown_Attribute <== Data Page | WARNING: PREVIOUS ATTRIBUTE
HAS TWO
0 Unknown_Attribute <== Threshold Page | INCONSISTENT IDENTITIES IN
THE DATA
211 Unknown_Attribute 0x3300 000 000 000 Old_age Offline
FAILING_NOW 281474959933440
211 Unknown_Attribute <== Data Page | WARNING: PREVIOUS ATTRIBUTE
HAS TWO
0 Unknown_Attribute <== Threshold Page | INCONSISTENT IDENTITIES IN
THE DATA
212 Unknown_Attribute 0x3100 000 076 000 Old_age Offline
FAILING_NOW 281474959933440
212 Unknown_Attribute <== Data Page | WARNING: PREVIOUS ATTRIBUTE
HAS TWO
0 Unknown_Attribute <== Threshold Page | INCONSISTENT IDENTITIES IN
THE DATA
213 Unknown_Attribute 0x3100 000 000 000 Old_age Offline
FAILING_NOW 281474959933440
213 Unknown_Attribute <== Data Page | WARNING: PREVIOUS ATTRIBUTE
HAS TWO
0 Unknown_Attribute <== Threshold Page | INCONSISTENT IDENTITIES IN
THE DATA
Warning: device does not support Error Logging
Error SMART Error Log Read failed: Input/output error
Smartctl: SMART Error Log Read Failed
Warning: device does not support Self Test Logging
Error SMART Error Self-Test Log Read failed: Input/output error
Smartctl: SMART Self Test Log Read Failed
Device does not support Selective Self Tests/Logging
------------------------------------------------------------------------------
Enter the BlackBerry Developer Challenge
This is your chance to win up to $100,000 in prizes! For a limited time,
vendors submitting new applications to BlackBerry App World(TM) will have
the opportunity to enter the BlackBerry Developer Challenge. See full prize
details at: http://p.sf.net/sfu/Challenge
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database