# smartctl -d ata -t short /dev/sdb
smartctl version 5.38 [x86_64-unknown-linux-gnu] Copyright (C) 2002-8 Bruce
Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF OFFLINE IMMEDIATE AND SELF-TEST SECTION ===
Sending command: "Execute SMART Short self-test routine immediately in off-line
mode".
Drive command "Execute SMART Short self-test routine immediately in off-line
mode" successful.
Testing has begun.
Please wait 2 minutes for test to complete.
Test will complete after Fri Dec 18 09:51:04 2009
Use smartctl -X to abort test.
bigserver:/home/arnem# smartctl -d ata -a /dev/sdb
smartctl version 5.38 [x86_64-unknown-linux-gnu] Copyright (C) 2002-8 Bruce
Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: WDC WD10EADS-00L5B1
Serial Number: WD-WCAU46179243
Firmware Version: 01.01A01
User Capacity: 1.000.204.886.016 bytes
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 8
ATA Standard is: Exact ATA specification draft version not indicated
Local Time is: Fri Dec 18 09:52:25 2009 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x85) Offline data collection activity
was aborted by an interrupting command
from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (22800) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 255) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x303f) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always
- 0
3 Spin_Up_Time 0x0027 163 163 021 Pre-fail Always
- 6833
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always
- 69
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always
- 0
7 Seek_Error_Rate 0x002e 100 253 000 Old_age Always
- 0
9 Power_On_Hours 0x0032 092 092 000 Old_age Always
- 6129
10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always
- 0
11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always
- 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always
- 10
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always
- 5
193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always
- 69
194 Temperature_Celsius 0x0022 123 114 000 Old_age Always
- 27
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always
- 0
197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always
- 0
198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline
- 0
199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always
- 0
200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline
- 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 6129 -
# 2 Short offline Completed without error 00% 6121 -
# 3 Short offline Completed without error 00% 6098 -
# 4 Short offline Completed without error 00% 6074 -
# 5 Short offline Completed without error 00% 6051 -
# 6 Short offline Completed without error 00% 6027 -
# 7 Short offline Completed without error 00% 6003 -
# 8 Extended offline Completed without error 00% 5985 -
# 9 Short offline Completed without error 00% 5980 -
#10 Short offline Completed without error 00% 5956 -
#11 Short offline Completed without error 00% 5933 -
#12 Short offline Completed without error 00% 5909 -
#13 Short offline Completed without error 00% 5886 -
#14 Short offline Completed without error 00% 5862 -
#15 Short offline Completed without error 00% 5842 -
#16 Extended offline Completed without error 00% 5820 -
#17 Short offline Completed without error 00% 5815 -
#18 Short offline Completed without error 00% 5791 -
#19 Short offline Completed without error 00% 5768 -
#20 Short offline Completed without error 00% 5744 -
#21 Short offline Completed without error 00% 5721 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
This SF.Net email is sponsored by the Verizon Developer Community
Take advantage of Verizon's best-in-class app development support
A streamlined, 14 day to market process makes app distribution fast and easy
Join now and get one step closer to millions of Verizon customers
http://p.sf.net/sfu/verizon-dev2dev
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net