Hi, I would like to ask to have the following SSD added to the DB. I've tested with the SVN build (reports smartctl 5.40 2010-01-01 r3025). I followed the wiki guide for getting information for the drive. After running the short self-test, and 'smartcl -c' showing that there is 0% of the test remaining, the selftest log is showing:
smartctl 5.40 2010-01-01 r3025 [x86_64-pc-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net === START OF READ SMART DATA SECTION === Warning! SMART Self-Test Log Structure error: invalid SMART checksum. SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] So I don't know if something is wrong... This is an SSD drive btw. I've attached smartctl -a output. Thanks in advance!
smartctl 5.40 2010-01-01 r3025 [x86_64-pc-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Device Model: CRUCIAL_CT64M225 Serial Number: P587665-RDBX-9299152 Firmware Version: 1571 User Capacity: 64,023,257,088 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 7 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Sat Jan 2 15:39:22 2010 EET SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 240) Self-test routine in progress... 00% of test remaining. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x1d) SMART execute Offline immediate. No Auto Offline data collection support. Abort Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x00) Error logging NOT supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 0) minutes. Extended self-test routine recommended polling time: ( 0) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x0000 007 000 000 Old_age Offline - 0 9 Power_On_Hours 0x0000 058 001 000 Old_age Offline - 0 12 Power_Cycle_Count 0x0000 068 001 000 Old_age Offline - 0 184 End-to-End_Error 0x0000 003 000 000 Old_age Offline - 0 195 Hardware_ECC_Recovered 0x0000 000 000 000 Old_age Offline - 0 196 Reallocated_Event_Count 0x0000 000 000 000 Old_age Offline - 0 197 Current_Pending_Sector 0x0000 000 000 000 Old_age Offline - 0 198 Offline_Uncorrectable 0x0000 069 241 000 Old_age Offline - 6426 199 UDMA_CRC_Error_Count 0x0000 025 156 000 Old_age Offline - 6600 200 Multi_Zone_Error_Rate 0x0000 224 065 000 Old_age Offline - 110 201 Soft_Read_Error_Rate 0x0000 130 043 000 Old_age Offline - 101 202 Data_Address_Mark_Errs 0x0000 044 096 000 Old_age Offline - 0 203 Run_Out_Cancel 0x0000 003 096 000 Old_age Offline - 0 204 Soft_ECC_Correction 0x0000 000 000 000 Old_age Offline - 0 205 Thermal_Asperity_Rate 0x0000 160 134 000 Old_age Offline - 1 206 Flying_Height 0x0000 001 000 000 Old_age Offline - 0 207 Spin_High_Current 0x0000 069 001 000 Old_age Offline - 0 208 Spin_Buzz 0x0000 014 000 000 Old_age Offline - 0 209 Offline_Seek_Performnce 0x0000 100 000 000 Old_age Offline - 0 210 Unknown_Attribute 0x0000 237 000 000 Old_age Offline - 0 211 Unknown_Attribute 0x0000 000 000 000 Old_age Offline - 0 Warning: device does not support Error Logging Warning! SMART ATA Error Log Structure error: invalid SMART checksum. SMART Error Log Version: 1 No Errors Logged Warning! SMART Self-Test Log Structure error: invalid SMART checksum. SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] Device does not support Selective Self Tests/Logging
------------------------------------------------------------------------------ This SF.Net email is sponsored by the Verizon Developer Community Take advantage of Verizon's best-in-class app development support A streamlined, 14 day to market process makes app distribution fast and easy Join now and get one step closer to millions of Verizon customers http://p.sf.net/sfu/verizon-dev2dev
_______________________________________________ Smartmontools-database mailing list Smartmontools-database@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/smartmontools-database