smartctl 5.40 2010-02-03 r3060 [i686-pc-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     Hitachi HDS721010CLA332
Serial Number:    JP2921HQ1RS8KA
Firmware Version: JP4OA39C
User Capacity:    1,000,204,886,016 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Mon Apr  5 01:12:36 2010 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x85) Offline data collection activity
                                        was aborted by an interrupting command 
from host.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                 (10399) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 173) minutes.
SCT capabilities:              (0x003d) SCT Status supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000b   054   054   016    Pre-fail  Always       
-       11423197
  2 Throughput_Performance  0x0005   135   135   054    Pre-fail  Offline      
-       96
  3 Spin_Up_Time            0x0007   100   100   024    Pre-fail  Always       
-       0
  4 Start_Stop_Count        0x0012   100   100   000    Old_age   Always       
-       4
  5 Reallocated_Sector_Ct   0x0033   100   100   005    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x000b   100   100   067    Pre-fail  Always       
-       0
  8 Seek_Time_Performance   0x0005   132   132   020    Pre-fail  Offline      
-       34
  9 Power_On_Hours          0x0012   100   100   000    Old_age   Always       
-       1071
 10 Spin_Retry_Count        0x0013   100   100   060    Pre-fail  Always       
-       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       4
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       
-       15
193 Load_Cycle_Count        0x0012   100   100   000    Old_age   Always       
-       15
194 Temperature_Celsius     0x0002   176   176   000    Old_age   Always       
-       34 (Lifetime Min/Max 23/36)
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       
-       0
197 Current_Pending_Sector  0x0022   100   100   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0008   100   100   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x000a   200   200   000    Old_age   Always       
-       0

SMART Error Log Version: 0
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%      1071         -
# 2  Extended offline    Completed without error       00%        77         -
# 3  Extended captive    Interrupted (host reset)      90%        74         -
# 4  Extended captive    Interrupted (host reset)      90%        74         -
# 5  Extended captive    Interrupted (host reset)      90%        74         -
# 6  Extended captive    Interrupted (host reset)      90%        74         -
# 7  Extended captive    Interrupted (host reset)      90%        74         -
# 8  Extended captive    Interrupted (host reset)      90%        74         -
# 9  Extended captive    Interrupted (host reset)      90%        74         -
#10  Extended captive    Interrupted (host reset)      90%        74         -
#11  Extended captive    Interrupted (host reset)      90%        74         -
#12  Extended captive    Interrupted (host reset)      90%        74         -
#13  Extended captive    Interrupted (host reset)      90%        74         -
#14  Extended captive    Interrupted (host reset)      90%        74         -
#15  Extended captive    Interrupted (host reset)      90%        74         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

------------------------------------------------------------------------------
Download Intel® Parallel Studio Eval
Try the new software tools for yourself. Speed compiling, find bugs
proactively, and fine-tune applications for parallel performance.
See why Intel Parallel Studio got high marks during beta.
http://p.sf.net/sfu/intel-sw-dev
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to