I would like to propose an update to the Transcend SSD database entry to
improve the display of vendor-specific attributes.  The attribute
descriptions are from the disk datasheet, pages 32 and 33.  Notes:

 1. The vendor-specific attributes of this drive are formatted in byte
order w012345r instead of 543210wv.  Also, the drive always reports
attributes 9 and 194 as zero.

 2. On my copy of smartctl, raw24/raw24 does not respond to custom byte
ordering.  In the enclosed output below, the correct result for
attribute 234 should be 646/720.

Please let me know if you have any questions.  Thank you!

Datasheet download address:

http://www.transcendusa.com/Products/ModDetail.asp?ModNo=177&SpNo=-100&LangNo=0

--------------------

{
  "Transcend Solid-State Drive",
  "TS(8|16|32|64|128)GSSD25-(M|S)",
  "",
  "",
  " -v 229,hex64:w012345r,Halt_System_ID"
  " -v 232,hex64:w012345r,Firmware_Date"
  " -v 233,hex48:w01234,ECC_Fail_Record"
  " -v 234,raw24/raw24:w01234,Average_Max_Erase"
  " -v 235,raw24/raw24:w01z23,Good_Free_Blocks"
}

--------------------

smartctl 5.40 2010-03-16 r3077 [i686-pc-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Model Family:     Transcend Solid-State Drive
Device Model:     TS32GSSD25-M
Serial Number:    xxxxxxxxxxxx (manually edited out)
Firmware Version: V090331
User Capacity:    32,044,482,560 bytes
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   7
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Wed May 26 13:37:45 2010 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Total time to complete Offline 
data collection:                 (   0) seconds.
Offline data collection
capabilities:                    (0x00)         Offline data collection not 
supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x00) Error logging NOT supported.
                                        General Purpose Logging supported.

SMART Attributes Data Structure revision number: 1280
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       238
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       
-       0
194 Temperature_Celsius     0x0007   032   100   000    Pre-fail  Always       
-       0
229 Halt_System_ID          0x0002   100   ---   000    Old_age   Always       
-       0x00ecd755b678ecd7
232 Firmware_Date           0x0002   100   ---   000    Old_age   Always       
-       0x3039303333310402
233 ECC_Fail_Record         0x0002   100   ---   000    Old_age   Always       
-       0x000000000000
234 Average_Max_Erase       0x0002   100   ---   000    Old_age   Always       
-       34306/53506
235 Good_Free_Blocks        0x0002   100   ---   000    Old_age   Always       
-       322623/52

Warning: device does not support Error Logging
Error SMART Error Log Read failed: Input/output error
Smartctl: SMART Error Log Read Failed
Warning: device does not support Self Test Logging
Error SMART Error Self-Test Log Read failed: Input/output error
Smartctl: SMART Self Test Log Read Failed
Device does not support Selective Self Tests/Logging

-- 
Chuan-kai Lin
http://web.cecs.pdx.edu/~cklin/

------------------------------------------------------------------------------

_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to