[r...@d9_00042 ~]# smartctl -a /dev/sdb
smartctl 5.40 2010-09-22 r3163 [x86_64-unknown-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen,
http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Model Family:     SandForce Driven SSDs
Device Model:     UGB99SGC100HB3
Serial Number:    UNIGEN-447994-000002
Firmware Version: RC Rev3
User Capacity:    100,030,242,816 bytes
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 6
Local Time is:    Thu Sep 23 16:40:35 2010 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
Error SMART Status command failed
Please get assistance from http://smartmontools.sourceforge.net/
Register values returned from SMART Status command are:
 ERR=...., SC=...., LL=...., LM=...., LH=...., DEV=...., STS=....
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.

General SMART Values:
Offline data collection status:  (0x02) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection:
Disabled.
Self-test execution status:      (   0) The previous self-test routine
completed
                                        without error or no self-test
has ever
                                        been run.
Total time to complete Offline
data collection:                 (   0) seconds.
Offline data collection
capabilities:                    (0x7f) SMART execute Offline immediate.
                                        Auto Offline data collection
on/off support.
                                        Abort Offline collection upon
new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging
supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (  48) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x003d) SCT Status supported.
                                        SCT Error Recovery Control
supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE
UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   105   100   050    Pre-fail  Always
-       0/11166221
  5 Retired_Block_Count     0x0033   100   100   003    Pre-fail  Always
-       0
  9 Power_On_Hours_and_Msec 0x0032   100   100   000    Old_age   Always
-       5h+05m+55.380s
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always
-       15
 13 Read_Soft_Error_Rate    0x000a   070   070   000    Old_age   Always
-       14864892977677
100 Unknown_Attribute       0x0032   000   000   000    Old_age   Always
-       0
170 Unknown_Attribute       0x0032   000   000   000    Old_age   Always
-       34496
171 Program_Fail_Count      0x0032   000   000   000    Old_age   Always
-       0
172 Erase_Fail_Count        0x0032   000   000   000    Old_age   Always
-       0
174 Unexpect_Power_Loss_Ct  0x0030   000   000   000    Old_age
Offline      -       11
177 Wear_Range_Delta        0x0000   000   000   000    Old_age
Offline      -       0
181 Program_Fail_Count      0x0032   000   000   000    Old_age   Always
-       0
182 Erase_Fail_Count        0x0032   000   000   000    Old_age   Always
-       0
184 End-to-End_Error        0x0032   100   100   090    Old_age   Always
-       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always
-       0
194 Temperature_Celsius     0x0022   029   045   000    Old_age   Always
-       29 (Lifetime Min/Max 21/45)
195 ECC_Uncorr_Error_Count  0x001c   105   100   000    Old_age
Offline      -       0/11166221
196 Reallocated_Event_Count 0x0033   100   100   003    Pre-fail  Always
-       0
198 Offline_Uncorrectable   0x0010   105   100   000    Old_age
Offline      -       107807974096896
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always
-       0
201 Soft_Read_Error_Rate    0x001c   105   100   000    Old_age
Offline      -       11166221
204 Soft_ECC_Correction     0x001c   105   100   000    Old_age
Offline      -       11166221
230 Head_Amplitude          0x0013   100   100   000    Pre-fail  Always
-       100
231 SSD_Life_Left           0x0013   100   100   010    Pre-fail  Always
-       0
232 Available_Reservd_Space 0x0000   000   000   000    Old_age
Offline      -       33
233 SandForce_Internal      0x0000   000   000   000    Old_age
Offline      -       0
234 SandForce_Internal      0x0032   000   000   000    Old_age   Always
-       64
235 Unknown_Attribute       0x0033   100   100   002    Pre-fail  Always
-       0
241 Lifetime_Writes_GiB     0x0032   000   000   000    Old_age   Always
-       64
242 Lifetime_Reads_GiB      0x0032   000   000   000    Old_age   Always
-       0

Error SMART Error Log Read failed: Input/output error
Smartctl: SMART Error Log Read Failed
Error SMART Error Self-Test Log Read failed: Input/output error
Smartctl: SMART Self Test Log Read Failed
SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute
delay.

-----Original Message-----
From: Christian Franke [mailto:christian.fra...@t-online.de] 
Sent: Wednesday, September 08, 2010 2:37 PM
To: Brad Jackson
Cc: smartmontools-database@lists.sourceforge.net
Subject: Re: [Smartmontools-database] Unigen SandForce based SSD support

Brad Jackson wrote:
>
> I am using Unigen UGB88PGC100HF2 drives based on the SandForce SF1200 
> controller and smartctl doesn't recognize them.
>
> Is there a way to force smartctl to treat them like other SandForce 
> drives?
>
>

Should work now with drivedb.h from current SVN.

The /usr(/local)/share/smartmontools/drivedb.h file from a recent build 
can be updated by running /usr(/local)/sbin/update-smart-drivedb

Thanks,
Christian


------------------------------------------------------------------------------
Start uncovering the many advantages of virtual appliances
and start using them to simplify application deployment and
accelerate your shift to cloud computing.
http://p.sf.net/sfu/novell-sfdev2dev
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to