smartctl 5.39.1 2010-01-28 r3054 [i686-pc-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION === Device Model: INTEL SSDSA2M080G2GC Serial Number: CVPO0170030C080JGN Firmware Version: 2CV102HD User Capacity: 80,026,361,856 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 7 ATA Standard is: ATA/ATAPI-7 T13 1532D revision 1 Local Time is: Tue Sep 21 19:49:25 2010 PDT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 1) seconds. Offline data collection capabilities: (0x75) SMART execute Offline immediate. No Auto Offline data collection support. Abort Offline collection upon new command. No Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 1) minutes. Conveyance self-test routine recommended polling time: ( 1) minutes. SMART Attributes Data Structure revision number: 5 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 3 Spin_Up_Time 0x0020 100 100 000 Old_age Offline - 0 4 Start_Stop_Count 0x0030 100 100 000 Old_age Offline - 0 5 Reallocated_Sector_Ct 0x0032 100 100 000 Old_age Always - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 87 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 23 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 6 225 Load_Cycle_Count 0x0030 200 200 000 Old_age Offline - 995 226 Load-in_Time 0x0032 100 100 000 Old_age Always - 5811 227 Torq-amp_Count 0x0032 100 100 000 Old_age Always - 0 228 Power-off_Retract_Count 0x0032 100 100 000 Old_age Always - 4278784880 232 Available_Reservd_Space 0x0033 100 100 010 Pre-fail Always - 0 233 Media_Wearout_Indicator 0x0032 099 099 000 Old_age Always - 0 184 End-to-End_Error 0x0033 100 100 099 Pre-fail Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Vendor offline Completed without error 00% 87 - # 2 Reserved offline Completed without error 00% 62 - Note: selective self-test log revision number (0) not 1 implies that no selective self-test has ever been run SMART Selective self-test log data structure revision number 0 Note: revision number not 1 implies that no selective self-test has ever been run SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. ------------------------------------------------------------------------------ Start uncovering the many advantages of virtual appliances and start using them to simplify application deployment and accelerate your shift to cloud computing. http://p.sf.net/sfu/novell-sfdev2dev _______________________________________________ Smartmontools-database mailing list Smartmontools-database@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/smartmontools-database