smartctl 5.39.1 2010-01-28 r3054 [i686-pc-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION === Device Model: Corsair CSSD-F40GB2 Serial Number: 10316505580010180041 Firmware Version: 1.1 User Capacity: 40,018,599,936 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 6 Local Time is: Tue Sep 21 19:45:10 2010 PDT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x02) Offline data collection activity was completed without error. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x7f) SMART execute Offline immediate. Auto Offline data collection on/off support. Abort Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 48) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 102 102 050 Pre-fail Always - 6482440 5 Reallocated_Sector_Ct 0x0033 089 089 003 Pre-fail Always - 1296 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 151758374436870 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 7 171 Unknown_Attribute 0x0000 000 000 000 Old_age Offline - 0 172 Unknown_Attribute 0x0000 000 000 000 Old_age Offline - 0 174 Unknown_Attribute 0x0030 000 000 000 Old_age Offline - 4 177 Wear_Leveling_Count 0x0000 000 000 --- Old_age Offline - 0 177 Wear_Leveling_Count <== Data Page | WARNING: PREVIOUS ATTRIBUTE HAS TWO 181 Program_Fail_Cnt_Total <== Threshold Page | INCONSISTENT IDENTITIES IN THE DATA 181 Program_Fail_Cnt_Total 0x0000 000 000 --- Old_age Offline - 0 181 Program_Fail_Cnt_Total <== Data Page | WARNING: PREVIOUS ATTRIBUTE HAS TWO 182 Erase_Fail_Count_Total <== Threshold Page | INCONSISTENT IDENTITIES IN THE DATA 182 Erase_Fail_Count_Total 0x0000 000 000 --- Old_age Offline - 0 182 Erase_Fail_Count_Total <== Data Page | WARNING: PREVIOUS ATTRIBUTE HAS TWO 187 Reported_Uncorrect <== Threshold Page | INCONSISTENT IDENTITIES IN THE DATA 187 Reported_Uncorrect 0x0032 100 100 --- Old_age Always - 0 187 Reported_Uncorrect <== Data Page | WARNING: PREVIOUS ATTRIBUTE HAS TWO 194 Temperature_Celsius <== Threshold Page | INCONSISTENT IDENTITIES IN THE DATA 194 Temperature_Celsius 0x0022 000 000 --- Old_age Always - 0 194 Temperature_Celsius <== Data Page | WARNING: PREVIOUS ATTRIBUTE HAS TWO 195 Hardware_ECC_Recovered <== Threshold Page | INCONSISTENT IDENTITIES IN THE DATA 195 Hardware_ECC_Recovered 0x001c 102 102 --- Old_age Offline - 6482440 195 Hardware_ECC_Recovered <== Data Page | WARNING: PREVIOUS ATTRIBUTE HAS TWO 196 Reallocated_Event_Count <== Threshold Page | INCONSISTENT IDENTITIES IN THE DATA 196 Reallocated_Event_Count 0x0033 100 100 --- Pre-fail Always - 0 196 Reallocated_Event_Count <== Data Page | WARNING: PREVIOUS ATTRIBUTE HAS TWO 231 Temperature_Celsius <== Threshold Page | INCONSISTENT IDENTITIES IN THE DATA 231 Temperature_Celsius 0x0013 086 086 --- Pre-fail Always - 1 231 Temperature_Celsius <== Data Page | WARNING: PREVIOUS ATTRIBUTE HAS TWO 233 Media_Wearout_Indicator <== Threshold Page | INCONSISTENT IDENTITIES IN THE DATA 233 Media_Wearout_Indicator 0x0000 000 000 --- Old_age Offline - 64 233 Media_Wearout_Indicator <== Data Page | WARNING: PREVIOUS ATTRIBUTE HAS TWO 234 Unknown_Attribute <== Threshold Page | INCONSISTENT IDENTITIES IN THE DATA 234 Unknown_Attribute 0x0000 000 000 --- Old_age Offline - 64 234 Unknown_Attribute <== Data Page | WARNING: PREVIOUS ATTRIBUTE HAS TWO 241 Total_LBAs_Written <== Threshold Page | INCONSISTENT IDENTITIES IN THE DATA 241 Total_LBAs_Written 0x0032 000 000 --- Old_age Always - 64 241 Total_LBAs_Written <== Data Page | WARNING: PREVIOUS ATTRIBUTE HAS TWO 242 Total_LBAs_Read <== Threshold Page | INCONSISTENT IDENTITIES IN THE DATA 242 Total_LBAs_Read 0x0032 000 000 --- Old_age Always - 128 Error SMART Error Log Read failed: Input/output error Smartctl: SMART Error Log Read Failed Error SMART Error Self-Test Log Read failed: Input/output error Smartctl: SMART Self Test Log Read Failed SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. ------------------------------------------------------------------------------ Start uncovering the many advantages of virtual appliances and start using them to simplify application deployment and accelerate your shift to cloud computing. http://p.sf.net/sfu/novell-sfdev2dev _______________________________________________ Smartmontools-database mailing list Smartmontools-database@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/smartmontools-database