This is the new Western Digital 3TB Green Power Advanced Format disk.  Nothing 
special in the way of vendor-specific display options were used with the drive 
and as far as I can tell, all the Attributes are behaving as other drives in 
the green power family.  This disk is hooked to a Mac so no special adapters or 
drivers were utilized.

Merle



smartctl 5.40 2010-10-16 r3189 [x86_64-apple-darwin10.4.2] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     WDC WD30EZRS-00J99B0
Serial Number:    WD-WMAWZ0024729
Firmware Version: 80.00A80
User Capacity:    3,000,592,982,016 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Sun Dec 19 10:35:31 2010 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x84) Offline data collection activity
                                        was suspended by an interrupting 
command from host.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                 (50460) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        ( 255) minutes.
Conveyance self-test routine
recommended polling time:        (   5) minutes.
SCT capabilities:              (0x3035) SCT Status supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002f   100   253   051    Pre-fail  Always       
-       0
  3 Spin_Up_Time            0x0027   100   253   021    Pre-fail  Always       
-       0
  4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       
-       4
  5 Reallocated_Sector_Ct   0x0033   200   200   140    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x002e   200   200   000    Old_age   Always       
-       0
  9 Power_On_Hours          0x0032   099   099   000    Old_age   Always       
-       1046
 10 Spin_Retry_Count        0x0032   100   253   000    Old_age   Always       
-       0
 11 Calibration_Retry_Count 0x0032   100   253   000    Old_age   Always       
-       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       3
192 Power-Off_Retract_Count 0x0032   200   200   000    Old_age   Always       
-       37
193 Load_Cycle_Count        0x0032   199   199   000    Old_age   Always       
-       3252
194 Temperature_Celsius     0x0022   114   113   000    Old_age   Always       
-       38
196 Reallocated_Event_Count 0x0032   200   200   000    Old_age   Always       
-       0
197 Current_Pending_Sector  0x0032   200   200   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0030   200   200   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x0032   200   200   000    Old_age   Always       
-       0
200 Multi_Zone_Error_Rate   0x0008   200   200   000    Old_age   Offline      
-       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%      1046         -
# 2  Extended offline    Completed without error       00%      1046         -
# 3  Short offline       Completed without error       00%      1014         -
# 4  Short offline       Completed without error       00%       990         -
# 5  Short offline       Completed without error       00%       966         -
# 6  Short offline       Completed without error       00%       942         -
# 7  Short offline       Completed without error       00%       918         -
# 8  Short offline       Completed without error       00%       894         -
# 9  Extended offline    Completed without error       00%       878         -
#10  Extended offline    Completed without error       00%       397         -
#11  Short offline       Completed without error       00%       295         -
#12  Short offline       Completed without error       00%       271         -
#13  Short offline       Completed without error       00%       247         -
#14  Short offline       Completed without error       00%       223         -
#15  Extended offline    Completed without error       00%       208         -
#16  Short offline       Completed without error       00%       175         -
#17  Short offline       Completed without error       00%       151         -
#18  Short offline       Completed without error       00%       128         -
#19  Short offline       Completed without error       00%       104         -
#20  Short offline       Completed without error       00%        80         -
#21  Short offline       Completed without error       00%        56         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.


------------------------------------------------------------------------------
Lotusphere 2011
Register now for Lotusphere 2011 and learn how
to connect the dots, take your collaborative environment
to the next level, and enter the era of Social Business.
http://p.sf.net/sfu/lotusphere-d2d
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to