Hi,
as far as I can see the latest drivedb.h version already contains the
Western Digital "Scorpio Blue" EIDE family:
[...]
{ "Western Digital Scorpio Blue EIDE family",
"WDC WD(4|6|8|10|12|16|25)00BEVE-.*",
"", "", ""
},
[...]
but the 320GB version is missing.
The output of
# smartctl -a /dev/sda
after a short offline self-test is attached.
Thanks,
Maurizio
smartctl 5.40 2010-07-12 r3124 [i686-pc-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Device Model: WDC WD3200BEVE-00A0HT0
Serial Number: WD-WXE209TLA490
Firmware Version: 11.01A11
User Capacity: 320,072,933,376 bytes
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 8
ATA Standard is: Exact ATA specification draft version not indicated
Local Time is: Tue Dec 28 12:51:00 2010 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x85) Offline data collection activity
was aborted by an interrupting command
from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (10380) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 122) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x2037) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always
- 42
3 Spin_Up_Time 0x0027 187 186 021 Pre-fail Always
- 1616
4 Start_Stop_Count 0x0032 099 099 000 Old_age Always
- 1207
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always
- 0
7 Seek_Error_Rate 0x002e 100 253 000 Old_age Always
- 0
9 Power_On_Hours 0x0032 096 096 000 Old_age Always
- 3517
10 Spin_Retry_Count 0x0033 100 100 051 Pre-fail Always
- 0
11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always
- 0
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always
- 1195
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always
- 51
193 Load_Cycle_Count 0x0032 185 185 000 Old_age Always
- 45983
194 Temperature_Celsius 0x0022 107 095 000 Old_age Always
- 40
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always
- 0
197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always
- 0
198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline
- 0
199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always
- 0
200 Multi_Zone_Error_Rate 0x0009 200 200 051 Pre-fail Offline
- 0
SMART Error Log Version: 1
ATA Error Count: 35 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 35 occurred at disk power-on lifetime: 810 hours (33 days + 18 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
01 51 05 bc 6d e1 e0 Error: AMNF at LBA = 0x00e16dbc = 14773692
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
24 00 05 bc 6d e1 02 08 00:07:38.196 READ SECTOR(S) EXT
24 00 05 bc 6d e1 02 08 00:07:35.219 READ SECTOR(S) EXT
24 00 05 bc 6d e1 02 08 00:07:32.125 READ SECTOR(S) EXT
10 00 3f 00 00 00 00 08 00:07:32.115 RECALIBRATE [OBS-4]
24 00 05 bc 6d e1 02 08 00:07:29.184 READ SECTOR(S) EXT
Error 34 occurred at disk power-on lifetime: 810 hours (33 days + 18 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
01 51 05 bc 6d e1 e0 Error: AMNF at LBA = 0x00e16dbc = 14773692
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
24 00 05 bc 6d e1 02 08 00:07:35.219 READ SECTOR(S) EXT
24 00 05 bc 6d e1 02 08 00:07:32.125 READ SECTOR(S) EXT
10 00 3f 00 00 00 00 08 00:07:32.115 RECALIBRATE [OBS-4]
24 00 05 bc 6d e1 02 08 00:07:29.184 READ SECTOR(S) EXT
24 00 05 bc 6d e1 02 08 00:07:25.934 READ SECTOR(S) EXT
Error 33 occurred at disk power-on lifetime: 810 hours (33 days + 18 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
01 51 05 bc 6d e1 e0 Error: AMNF at LBA = 0x00e16dbc = 14773692
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
24 00 05 bc 6d e1 02 08 00:07:32.125 READ SECTOR(S) EXT
10 00 3f 00 00 00 00 08 00:07:32.115 RECALIBRATE [OBS-4]
24 00 05 bc 6d e1 02 08 00:07:29.184 READ SECTOR(S) EXT
24 00 05 bc 6d e1 02 08 00:07:25.934 READ SECTOR(S) EXT
24 00 05 bc 6d e1 02 08 00:07:22.801 READ SECTOR(S) EXT
Error 32 occurred at disk power-on lifetime: 810 hours (33 days + 18 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
01 51 05 bc 6d e1 e0 Error: AMNF at LBA = 0x00e16dbc = 14773692
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
24 00 05 bc 6d e1 02 08 00:07:29.184 READ SECTOR(S) EXT
24 00 05 bc 6d e1 02 08 00:07:25.934 READ SECTOR(S) EXT
24 00 05 bc 6d e1 02 08 00:07:22.801 READ SECTOR(S) EXT
24 00 05 bc 6d e1 02 08 00:07:19.862 READ SECTOR(S) EXT
10 00 3f 00 00 00 00 08 00:07:19.841 RECALIBRATE [OBS-4]
Error 31 occurred at disk power-on lifetime: 810 hours (33 days + 18 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
01 51 05 bc 6d e1 e0 Error: AMNF at LBA = 0x00e16dbc = 14773692
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
24 00 05 bc 6d e1 02 08 00:07:25.934 READ SECTOR(S) EXT
24 00 05 bc 6d e1 02 08 00:07:22.801 READ SECTOR(S) EXT
24 00 05 bc 6d e1 02 08 00:07:19.862 READ SECTOR(S) EXT
10 00 3f 00 00 00 00 08 00:07:19.841 RECALIBRATE [OBS-4]
24 00 05 bc 6d e1 02 08 00:07:16.914 READ SECTOR(S) EXT
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 3517 -
# 2 Short offline Completed without error 00% 3517 -
# 3 Short offline Completed without error 00% 3508 -
# 4 Extended offline Completed without error 00% 3508 -
# 5 Short offline Completed without error 00% 3503 -
# 6 Short offline Completed without error 00% 3497 -
# 7 Short offline Completed without error 00% 3487 -
# 8 Short offline Completed without error 00% 3478 -
# 9 Short offline Completed without error 00% 3470 -
#10 Extended offline Completed without error 00% 3469 -
#11 Short offline Completed without error 00% 3462 -
#12 Short offline Completed without error 00% 3455 -
#13 Short offline Completed without error 00% 3446 -
#14 Short offline Completed without error 00% 3440 -
#15 Short offline Completed without error 00% 3431 -
#16 Extended offline Interrupted (host reset) 90% 3428 -
#17 Short offline Completed without error 00% 3423 -
#18 Short offline Completed without error 00% 3414 -
#19 Short offline Completed without error 00% 3410 -
#20 Short offline Completed without error 00% 3403 -
#21 Short offline Completed without error 00% 3393 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
Learn how Oracle Real Application Clusters (RAC) One Node allows customers
to consolidate database storage, standardize their database environment, and,
should the need arise, upgrade to a full multi-node Oracle RAC database
without downtime or disruption
http://p.sf.net/sfu/oracle-sfdevnl
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database