Robert M. Stockmann - RHCE
Network Engineer - UNIX/Linux Specialist
crashrecovery.org  st...@stokkie.net
smartctl 5.40 2010-10-16 r3189 [x86_64-mandrake-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     ST32000641AS
Serial Number:    9WM13RCC
Firmware Version: CC13
User Capacity:    2,000,398,934,016 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Thu Jan 13 01:00:48 2011 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                 ( 609) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 255) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   104   099   006    Pre-fail  Always       
-       6345604
  3 Spin_Up_Time            0x0003   100   100   000    Pre-fail  Always       
-       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       
-       10
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x000f   100   253   030    Pre-fail  Always       
-       786141
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       
-       25
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       
-       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       
-       8
183 Runtime_Bad_Block       0x0032   100   100   000    Old_age   Always       
-       0
184 End-to-End_Error        0x0032   100   100   099    Old_age   Always       
-       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       
-       0
188 Command_Timeout         0x0032   100   100   000    Old_age   Always       
-       0
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       
-       0
190 Airflow_Temperature_Cel 0x0022   057   056   045    Old_age   Always       
-       43 (Min/Max 37/44)
191 G-Sense_Error_Rate      0x0032   100   100   000    Old_age   Always       
-       0
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       
-       7
193 Load_Cycle_Count        0x0032   100   100   000    Old_age   Always       
-       8
194 Temperature_Celsius     0x0022   043   044   000    Old_age   Always       
-       43 (0 24 0 0)
195 Hardware_ECC_Recovered  0x001a   026   026   000    Old_age   Always       
-       6345604
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       
-       0
240 Head_Flying_Hours       0x0000   100   253   000    Old_age   Offline      
-       79018808311838
241 Total_LBAs_Written      0x0000   100   253   000    Old_age   Offline      
-       791290008
242 Total_LBAs_Read         0x0000   100   253   000    Old_age   Offline      
-       52329

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%        25         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

------------------------------------------------------------------------------
Special Offer-- Download ArcSight Logger for FREE (a $49 USD value)!
Finally, a world-class log management solution at an even better price-free!
Download using promo code Free_Logger_4_Dev2Dev. Offer expires 
February 28th, so secure your free ArcSight Logger TODAY! 
http://p.sf.net/sfu/arcsight-sfd2d
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to