smartctl 5.40 2010-07-12 r3124 [i686-pc-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     FM-25S2I-64GBFII
Serial Number:    DC2210090F1B41183
Firmware Version: 1916
User Capacity:    64.023.257.088 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Sat Mar  5 18:00:08 2011 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      ( 240) Self-test routine in progress...
                                        00% of test remaining.
Total time to complete Offline 
data collection:                 (   0) seconds.
Offline data collection
capabilities:                    (0x1d) SMART execute Offline immediate.
                                        No Auto Offline data collection support.
                                        Abort Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        No Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x00) Error logging NOT supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   0) minutes.
Extended self-test routine
recommended polling time:        (   0) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x0000   006   000   000    Old_age   Offline      
-       0
  9 Power_On_Hours          0x0000   144   007   000    Old_age   Offline      
-       0
 12 Power_Cycle_Count       0x0000   026   001   000    Old_age   Offline      
-       0
184 End-to-End_Error        0x0000   136   000   000    Old_age   Offline      
-       0
195 Hardware_ECC_Recovered  0x0000   000   000   000    Old_age   Offline      
-       0
196 Reallocated_Event_Count 0x0000   000   000   000    Old_age   Offline      
-       0
197 Current_Pending_Sector  0x0000   000   000   000    Old_age   Offline      
-       0
198 Offline_Uncorrectable   0x0000   217   252   000    Old_age   Offline      
-       37148
199 UDMA_CRC_Error_Count    0x0000   108   053   000    Old_age   Offline      
-       35227
200 Multi_Zone_Error_Rate   0x0000   209   082   000    Old_age   Offline      
-       627
201 Soft_Read_Error_Rate    0x0000   093   104   000    Old_age   Offline      
-       725
202 Data_Address_Mark_Errs  0x0000   135   188   000    Old_age   Offline      
-       89
203 Run_Out_Cancel          0x0000   002   127   000    Old_age   Offline      
-       84
204 Soft_ECC_Correction     0x0000   000   000   000    Old_age   Offline      
-       0
205 Thermal_Asperity_Rate   0x0000   016   039   000    Old_age   Offline      
-       0
206 Flying_Height           0x0000   157   000   000    Old_age   Offline      
-       0
207 Spin_High_Current       0x0000   225   003   000    Old_age   Offline      
-       0
208 Spin_Buzz               0x0000   091   002   000    Old_age   Offline      
-       0
209 Offline_Seek_Performnce 0x0000   094   000   000    Old_age   Offline      
-       0
211 Unknown_Attribute       0x0000   000   000   000    Old_age   Offline      
-       0
212 Unknown_Attribute       0x0000   019   016   000    Old_age   Offline      
-       0
213 Unknown_Attribute       0x0000   000   000   000    Old_age   Offline      
-       0

Warning: device does not support Error Logging
Warning! SMART ATA Error Log Structure error: invalid SMART checksum.
SMART Error Log Version: 1
No Errors Logged

Warning! SMART Self-Test Log Structure error: invalid SMART checksum.
SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


Device does not support Selective Self Tests/Logging
------------------------------------------------------------------------------
What You Don't Know About Data Connectivity CAN Hurt You
This paper provides an overview of data connectivity, details
its effect on application quality, and explores various alternative
solutions. http://p.sf.net/sfu/progress-d2d
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to