Please find attached my Seagate 250GB SATA HDD that is showing up as not in
the smartmon database

 

 

=== START OF INFORMATION SECTION ===
Device Model:     VB0250EAVER
Serial Number:    9VMRBKR7
Firmware Version: HPG0
User Capacity:    250,059,350,016 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  Not recognized. Minor revision code: 0x28
Local Time is:    Mon Mar 28 10:55:25 2011 BST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                 ( 634) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  46) minutes.
SCT capabilities:              (0x103d) SCT Status supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002f   115   099   006    Pre-fail  Always       
-       96780770
  3 Spin_Up_Time            0x0023   097   097   000    Pre-fail  Always       
-       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       
-       472
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x002f   100   253   030    Pre-fail  Always       
-       139586
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       
-       112
 10 Spin_Retry_Count        0x0033   100   100   097    Pre-fail  Always       
-       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       
-       14
180 Unknown_Attribute       0x002b   100   100   000    Pre-fail  Always       
-       908459706
183 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       
-       0
184 Unknown_Attribute       0x0032   100   100   097    Old_age   Always       
-       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       
-       0
188 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       
-       0
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       
-       0
190 Airflow_Temperature_Cel 0x0022   078   068   045    Old_age   Always       
-       22 (Lifetime Min/Max 16/27)
194 Temperature_Celsius     0x0022   022   040   000    Old_age   Always       
-       22 (0 16 0 0)
195 Hardware_ECC_Recovered  0x003a   051   049   000    Old_age   Always       
-       96780770
196 Reallocated_Event_Count 0x0032   100   100   036    Old_age   Always       
-       0
197 Current_Pending_Sector  0x0032   100   100   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0030   100   100   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x0032   200   200   000    Old_age   Always       
-       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%       112         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

------------------------------------------------------------------------------
Enable your software for Intel(R) Active Management Technology to meet the
growing manageability and security demands of your customers. Businesses
are taking advantage of Intel(R) vPro (TM) technology - will your software 
be a part of the solution? Download the Intel(R) Manageability Checker 
today! http://p.sf.net/sfu/intel-dev2devmar
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to