Kevin Crosbie 
Lead Systems Programmer
open gi
Buckholt Drive, Warndon, Worcester WR4 9SR 
Tel:    +44 (0)1905 754455     Ext:   2135
Fax:   +44 (0)1905 754441
Email:  kevin.cros...@opengi.co.uk 
Web:  www.opengi.co.uk <http://www.opengi.co.uk/> 

 

powering broker business for 30 years




Please consider the environment before printing this e-mail 




"This message is intended for the named recipient only and may be
privileged and/or confidential. If you are not the intended or named
recipient or have received this email in error then you should not copy
forward or disclose it to any other persons. If you have received this
email in error you should destroy it and contact the sender so that we
may take appropriate action. The views and opinions expressed in this
email may not represent the views and opinions of Open International
Limited or any of its subsidiaries and are made without prejudice and
subject to contract. The Company Reserves the right to intercept and
review all email communications." 

 

Open International Limited. Registered Office: Buckholt Drive, Warndon,
Worcester, WR4 9SR. 
Registered in England. Registered No: 05716519 

 

 

smartctl 5.40 2010-10-16 r3189 [i686-pc-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     WDC WD800AAJS-00B4A0
Serial Number:    WD-WMAT22261231
Firmware Version: 01.03A01
User Capacity:    80,026,361,856 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Wed Apr 13 11:10:11 2011 BST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x85) Offline data collection activity
                                        was aborted by an interrupting command 
from host.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                 (2460) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  33) minutes.
Conveyance self-test routine
recommended polling time:        (   5) minutes.
SCT capabilities:              (0x303f) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002f   200   200   051    Pre-fail  Always       
-       0
  3 Spin_Up_Time            0x0027   157   154   021    Pre-fail  Always       
-       3150
  4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       
-       71
  5 Reallocated_Sector_Ct   0x0033   200   200   140    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x002e   200   200   000    Old_age   Always       
-       0
  9 Power_On_Hours          0x0032   097   097   000    Old_age   Always       
-       2776
 10 Spin_Retry_Count        0x0032   100   253   000    Old_age   Always       
-       0
 11 Calibration_Retry_Count 0x0032   100   253   000    Old_age   Always       
-       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       69
192 Power-Off_Retract_Count 0x0032   200   200   000    Old_age   Always       
-       53
193 Load_Cycle_Count        0x0032   200   200   000    Old_age   Always       
-       71
194 Temperature_Celsius     0x0022   114   098   000    Old_age   Always       
-       29
196 Reallocated_Event_Count 0x0032   200   200   000    Old_age   Always       
-       0
197 Current_Pending_Sector  0x0032   200   200   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0030   200   200   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x0032   200   200   000    Old_age   Always       
-       0
200 Multi_Zone_Error_Rate   0x0008   200   200   000    Old_age   Offline      
-       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Extended offline    Completed without error       00%      2776         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

------------------------------------------------------------------------------
Benefiting from Server Virtualization: Beyond Initial Workload 
Consolidation -- Increasing the use of server virtualization is a top
priority.Virtualization can reduce costs, simplify management, and improve 
application availability and disaster protection. Learn more about boosting 
the value of server virtualization. http://p.sf.net/sfu/vmware-sfdev2dev
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to