Please find attached smartctl commands (smartctl -t short /dev/sda and
smartctl -a /dev/sda in my case) output for the ADATA S599 (40GB
capacity) SATA II SSD

ADATA's SSD S599 manufacturer URL:
http://www.adata-group.com/index.php?action=product_specification&cid=3&piid=33

Regards,
Davide Poletto.
[root@akira ~]#  smartctl -t short /dev/sda
smartctl 5.40 2010-10-16 r3189 [x86_64-redhat-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF OFFLINE IMMEDIATE AND SELF-TEST SECTION ===
Sending command: "Execute SMART Short self-test routine immediately in off-line 
mode".
Drive command "Execute SMART Short self-test routine immediately in off-line 
mode" successful.
Testing has begun.
Please wait 1 minutes for test to complete.
Test will complete after Tue May 10 08:20:30 2011

Use smartctl -X to abort test.
[root@akira ~]# smartctl -a /dev/sda
smartctl 5.40 2010-10-16 r3189 [x86_64-redhat-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     ADATA SSD S599 40GB
Serial Number:    00000000000000000485
Firmware Version: 3.2.0
User Capacity:    40,018,599,936 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 6
Local Time is:    Tue May 10 08:25:26 2011 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x02) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                 (   0) seconds.
Offline data collection
capabilities:                    (0x7f) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Abort Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (  48) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x003d) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   104   099   050    Pre-fail  Always       
-       8415121
  5 Reallocated_Sector_Ct   0x0033   099   099   003    Pre-fail  Always       
-       120
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       
-       229394203279951
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       218
171 Unknown_Attribute       0x0000   000   000   000    Old_age   Offline      
-       0
172 Unknown_Attribute       0x0000   000   000   000    Old_age   Offline      
-       0
174 Unknown_Attribute       0x0030   000   000   000    Old_age   Offline      
-       30
177 Wear_Leveling_Count     0x0000   000   000   ---    Old_age   Offline      
-       0
181 Program_Fail_Cnt_Total  0x0000   000   000   000    Old_age   Offline      
-       0
182 Erase_Fail_Count_Total  0x0000   000   000   000    Old_age   Offline      
-       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       
-       0
194 Temperature_Celsius     0x0022   029   033   000    Old_age   Always       
-       29 (Min/Max 0/33)
195 Hardware_ECC_Recovered  0x001c   104   099   000    Old_age   Offline      
-       8415121
196 Reallocated_Event_Count 0x0033   100   100   003    Pre-fail  Always       
-       0
231 Temperature_Celsius     0x0013   099   099   010    Pre-fail  Always       
-       1
233 Media_Wearout_Indicator 0x0000   000   000   000    Old_age   Offline      
-       0
234 Unknown_Attribute       0x0000   000   000   000    Old_age   Offline      
-       64
241 Total_LBAs_Written      0x0032   000   000   000    Old_age   Always       
-       64
242 Total_LBAs_Read         0x0032   000   000   000    Old_age   Always       
-       384

Error SMART Error Log Read failed: Input/output error
Smartctl: SMART Error Log Read Failed
Error SMART Error Self-Test Log Read failed: Input/output error
Smartctl: SMART Self Test Log Read Failed
SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

------------------------------------------------------------------------------
Achieve unprecedented app performance and reliability
What every C/C++ and Fortran developer should know.
Learn how Intel has extended the reach of its next-generation tools
to help boost performance applications - inlcuding clusters.
http://p.sf.net/sfu/intel-dev2devmay
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to