-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA1

Yo All!

I have a shiny new 120GB Intel SSD.  Not in the smartmontools database
and I can not figure out how to read the self test results.

The results of this attached:
        smartctl -t short /dev/sdd
        [ wait 3 min]
        smartctl -a /dev/sdd

RGDS
GARY
- ---------------------------------------------------------------------------
Gary E. Miller Rellim 109 NW Wilmington Ave., Suite E, Bend, OR 97701
        g...@rellim.com  Tel:+1(541)382-8588
-----BEGIN PGP SIGNATURE-----
Version: GnuPG v1.4.3 (GNU/Linux)

iD8DBQFN4zfoBmnRqz71OvMRAi22AJ0U2HUlgwh55EPhTkSa/qM8+2xqNwCfT9gL
dBOemap4JZRijsAvJ3vu06M=
=i39U
-----END PGP SIGNATURE-----
smartctl 5.40 2010-10-16 r3189 [x86_64-pc-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     INTEL SSDSC2MH120A2
Serial Number:    LNEL111300R4120CGN
Firmware Version: PPG2
User Capacity:    120,034,123,776 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 2d
Local Time is:    Sun May 29 23:19:42 2011 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                 (  10) seconds.
Offline data collection
capabilities:                    (0x15) SMART execute Offline immediate.
                                        No Auto Offline data collection support.
                                        Abort Offline collection upon new
                                        command.
                                        No Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        No Selective Self-test supported.
SMART capabilities:            (0x0002) Does not save SMART data before
                                        entering power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x00) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  10) minutes.
SCT capabilities:              (0x003d) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  3 Spin_Up_Time            0x0020   100   100   000    Old_age   Offline      
-       0
  4 Start_Stop_Count        0x0030   100   100   000    Old_age   Offline      
-       0
  5 Reallocated_Sector_Ct   0x0032   100   100   000    Old_age   Always       
-       0
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       
-       1
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       4
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       
-       4
225 Load_Cycle_Count        0x0030   100   100   000    Old_age   Offline      
-       1878
232 Available_Reservd_Space 0x0033   100   100   010    Pre-fail  Always       
-       0
233 Media_Wearout_Indicator 0x0032   100   100   000    Old_age   Always       
-       0

Error SMART Error Log Read failed: Input/output error
Smartctl: SMART Error Log Read Failed
SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


Device does not support Selective Self Tests/Logging
------------------------------------------------------------------------------
vRanger cuts backup time in half-while increasing security.
With the market-leading solution for virtual backup and recovery, 
you get blazing-fast, flexible, and affordable data protection.
Download your free trial now. 
http://p.sf.net/sfu/quest-d2dcopy1
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to