-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA1
Yo All!
I have a shiny new 120GB Intel SSD. Not in the smartmontools database
and I can not figure out how to read the self test results.
The results of this attached:
smartctl -t short /dev/sdd
[ wait 3 min]
smartctl -a /dev/sdd
RGDS
GARY
- ---------------------------------------------------------------------------
Gary E. Miller Rellim 109 NW Wilmington Ave., Suite E, Bend, OR 97701
g...@rellim.com Tel:+1(541)382-8588
-----BEGIN PGP SIGNATURE-----
Version: GnuPG v1.4.3 (GNU/Linux)
iD8DBQFN4zfoBmnRqz71OvMRAi22AJ0U2HUlgwh55EPhTkSa/qM8+2xqNwCfT9gL
dBOemap4JZRijsAvJ3vu06M=
=i39U
-----END PGP SIGNATURE-----
smartctl 5.40 2010-10-16 r3189 [x86_64-pc-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Device Model: INTEL SSDSC2MH120A2
Serial Number: LNEL111300R4120CGN
Firmware Version: PPG2
User Capacity: 120,034,123,776 bytes
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 8
ATA Standard is: ATA-8-ACS revision 2d
Local Time is: Sun May 29 23:19:42 2011 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 10) seconds.
Offline data collection
capabilities: (0x15) SMART execute Offline immediate.
No Auto Offline data collection support.
Abort Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0002) Does not save SMART data before
entering power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x00) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 10) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
3 Spin_Up_Time 0x0020 100 100 000 Old_age Offline
- 0
4 Start_Stop_Count 0x0030 100 100 000 Old_age Offline
- 0
5 Reallocated_Sector_Ct 0x0032 100 100 000 Old_age Always
- 0
9 Power_On_Hours 0x0032 100 100 000 Old_age Always
- 1
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always
- 4
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always
- 4
225 Load_Cycle_Count 0x0030 100 100 000 Old_age Offline
- 1878
232 Available_Reservd_Space 0x0033 100 100 010 Pre-fail Always
- 0
233 Media_Wearout_Indicator 0x0032 100 100 000 Old_age Always
- 0
Error SMART Error Log Read failed: Input/output error
Smartctl: SMART Error Log Read Failed
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
Device does not support Selective Self Tests/Logging
------------------------------------------------------------------------------
vRanger cuts backup time in half-while increasing security.
With the market-leading solution for virtual backup and recovery,
you get blazing-fast, flexible, and affordable data protection.
Download your free trial now.
http://p.sf.net/sfu/quest-d2dcopy1
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database