Hi,
please consider this disc for the database.
--
Mit freundlichen Gruessen / yours sincerely
Sebastian Urbach
----------------------------------------------------------
Convictions are more dangerous enemies of truth than lies.
----------------------------------------------------------
Friedrich Nietzsche (1844 - 1900)
German philosopher, poet and classical philologist
smartctl 5.41 2011-03-16 r3296 [x86_64-unknown-linux-gnu-2.6.39-2-amd64] (local
build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Device Model: WDC WD1003FBYX-01Y7B0
Serial Number: WD-WCAW31592568
Firmware Version: 01.01V01
User Capacity: 1.000.204.886.016 bytes
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 8
ATA Standard is: Exact ATA specification draft version not indicated
Local Time is: Tue Jun 14 10:01:40 2011 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x85) Offline data collection activity
was aborted by an interrupting command
from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 121) The previous self-test completed having
the read element of the test failed.
Total time to complete Offline
data collection: (16680) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 172) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x303f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 157 057 051 Pre-fail Always
- 2312
3 Spin_Up_Time 0x0027 183 174 021 Pre-fail Always
- 3816
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always
- 36
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always
- 0
7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always
- 0
9 Power_On_Hours 0x0032 100 100 000 Old_age Always
- 44
10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always
- 0
11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always
- 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always
- 34
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always
- 30
193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always
- 5
194 Temperature_Celsius 0x0022 109 106 000 Old_age Always
- 38
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always
- 0
197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always
- 41
198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline
- 0
199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always
- 0
200 Multi_Zone_Error_Rate 0x0008 100 253 000 Old_age Offline
- 0
SMART Error Log Version: 1
ATA Error Count: 25 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 25 occurred at disk power-on lifetime: 26 hours (1 days + 2 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 08 0b 10 80 ed Error: UNC 8 sectors at LBA = 0x0d80100b = 226496523
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 08 10 80 ed 00 05:57:06.489 READ DMA
c8 00 08 68 10 00 ef 00 05:57:06.489 READ DMA
c8 00 08 00 10 c0 e0 00 05:57:06.449 READ DMA
Error 24 occurred at disk power-on lifetime: 25 hours (1 days + 1 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 08 0b 10 80 ed Error: UNC 8 sectors at LBA = 0x0d80100b = 226496523
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 08 10 80 ed 08 04:52:26.846 READ DMA
ec 00 00 00 00 00 a0 08 04:52:26.844 IDENTIFY DEVICE
ef 03 46 00 00 00 a0 08 04:52:26.844 SET FEATURES [Set transfer mode]
Error 23 occurred at disk power-on lifetime: 25 hours (1 days + 1 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 08 0b 10 80 ed Error: UNC 8 sectors at LBA = 0x0d80100b = 226496523
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 08 10 80 ed 08 04:52:25.122 READ DMA
ec 00 00 00 00 00 a0 08 04:52:25.120 IDENTIFY DEVICE
ef 03 46 00 00 00 a0 08 04:52:25.120 SET FEATURES [Set transfer mode]
Error 22 occurred at disk power-on lifetime: 25 hours (1 days + 1 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 08 0b 10 80 ed Error: UNC 8 sectors at LBA = 0x0d80100b = 226496523
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 08 10 80 ed 08 04:52:23.408 READ DMA
ec 00 00 00 00 00 a0 08 04:52:23.406 IDENTIFY DEVICE
ef 03 46 00 00 00 a0 08 04:52:23.406 SET FEATURES [Set transfer mode]
Error 21 occurred at disk power-on lifetime: 25 hours (1 days + 1 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 08 0b 10 80 ed Error: UNC 8 sectors at LBA = 0x0d80100b = 226496523
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 08 10 80 ed 08 04:52:21.568 READ DMA
ec 00 00 00 00 00 a0 08 04:52:21.566 IDENTIFY DEVICE
ef 03 46 00 00 00 a0 08 04:52:21.566 SET FEATURES [Set transfer mode]
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed: read failure 90% 44
69584560
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
EditLive Enterprise is the world's most technically advanced content
authoring tool. Experience the power of Track Changes, Inline Image
Editing and ensure content is compliant with Accessibility Checking.
http://p.sf.net/sfu/ephox-dev2dev
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database