smartctl does not recognize this drive:

 | $ smartctl -a /dev/sdb
 | smartctl 5.41 2011-06-09 r3365 [x86_64-linux-2.6.38.4] (local build)
 | Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
 |
 | /dev/sdb: Unknown USB bridge [0x07ab:0xfc88 (0x101)]
 | Smartctl: please specify device type with the -d option.
 |
 | Use smartctl -h to get a usage summary

It does, mostly though, when told to use usbjmicron:

 | $ smartctl -d usbjmicron -a /dev/sdb
 | smartctl 5.41 2011-06-09 r3365 [x86_64-linux-2.6.38.4] (local build)
 | Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
 |
 | === START OF INFORMATION SECTION ===
 | Device Model:     SAMSUNG HM252HX
 | Serial Number:    C1042F121A031I
 | LU WWN Device Id: 5 0000f0 01afb1003
 | Firmware Version: 2AC101C4
 | User Capacity:    250,059,350,016 bytes [250 GB]
 | Sector Size:      512 bytes logical/physical
 | Device is:        Not in smartctl database [for details use: -P showall]
 | ATA Version is:   8
 | ATA Standard is:  ATA-8-ACS revision 6
 | Local Time is:    Sat Jul 23 16:46:19 2011 CEST
 | SMART support is: Available - device has SMART capability.
 | SMART support is: Enabled
 |
 | === START OF READ SMART DATA SECTION ===
 | SMART overall-health self-assessment test result: PASSED
 |
 | General SMART Values:
 | Offline data collection status:  (0x00)      Offline data collection activity
 |                                      was never started.
 |                                      Auto Offline Data Collection: Disabled.
 | Self-test execution status:      (   0)      The previous self-test routine 
completed
 |                                      without error or no self-test has ever
 |                                      been run.
 | Total time to complete Offline
 | data collection:             ( 4200) seconds.
 | Offline data collection
 | capabilities:                         (0x5b) SMART execute Offline immediate.
 |                                      Auto Offline data collection on/off 
support.
 |                                      Suspend Offline collection upon new
 |                                      command.
 |                                      Offline surface scan supported.
 |                                      Self-test supported.
 |                                      No Conveyance Self-test supported.
 |                                      Selective Self-test supported.
 | SMART capabilities:            (0x0003)      Saves SMART data before entering
 |                                      power-saving mode.
 |                                      Supports SMART auto save timer.
 | Error logging capability:        (0x01)      Error logging supported.
 |                                      General Purpose Logging supported.
 | Short self-test routine
 | recommended polling time:     (   2) minutes.
 | Extended self-test routine
 | recommended polling time:     (  70) minutes.
 | SCT capabilities:           (0x003f) SCT Status supported.
 |                                      SCT Error Recovery Control supported.
 |                                      SCT Feature Control supported.
 |                                      SCT Data Table supported.
 |
 | SMART Attributes Data Structure revision number: 16
 | Vendor Specific SMART Attributes with Thresholds:
 | ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
 |   1 Raw_Read_Error_Rate     0x002f   100   100   051    Pre-fail  Always     
  -       0
 |   2 Throughput_Performance  0x0026   252   252   000    Old_age   Always     
  -       0
 |   3 Spin_Up_Time            0x0023   091   091   025    Pre-fail  Always     
  -       2850
 |   4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always     
  -       147
 |   5 Reallocated_Sector_Ct   0x0033   252   252   010    Pre-fail  Always     
  -       0
 |   7 Seek_Error_Rate         0x002e   252   252   051    Old_age   Always     
  -       0
 |   8 Seek_Time_Performance   0x0024   252   252   015    Old_age   Offline    
  -       0
 |   9 Power_On_Hours          0x0032   100   100   000    Old_age   Always     
  -       74
 |  10 Spin_Retry_Count        0x0032   252   252   051    Old_age   Always     
  -       0
 |  11 Calibration_Retry_Count 0x0032   100   100   000    Old_age   Always     
  -       13
 |  12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always     
  -       79
 | 191 G-Sense_Error_Rate      0x0022   100   100   000    Old_age   Always     
  -       38
 | 192 Power-Off_Retract_Count 0x0022   252   252   000    Old_age   Always     
  -       0
 | 194 Temperature_Celsius     0x0002   064   064   000    Old_age   Always     
  -       28 (Min/Max 14/42)
 | 195 Hardware_ECC_Recovered  0x003a   100   100   000    Old_age   Always     
  -       0
 | 196 Reallocated_Event_Count 0x0032   252   252   000    Old_age   Always     
  -       0
 | 197 Current_Pending_Sector  0x0032   252   252   000    Old_age   Always     
  -       0
 | 198 Offline_Uncorrectable   0x0030   252   252   000    Old_age   Offline    
  -       0
 | 199 UDMA_CRC_Error_Count    0x0036   200   200   000    Old_age   Always     
  -       0
 | 200 Multi_Zone_Error_Rate   0x002a   100   100   000    Old_age   Always     
  -       3
 | 223 Load_Retry_Count        0x0032   100   100   000    Old_age   Always     
  -       13
 | 225 Load_Cycle_Count        0x0032   100   100   000    Old_age   Always     
  -       2013
 |
 | SMART Error Log Version: 1
 | No Errors Logged
 |
 | SMART Self-test log structure revision number 1
 | No self-tests have been logged.  [To run self-tests, use: smartctl -t]
 |
 |
 | Note: selective self-test log revision number (0) not 1 implies that no 
selective self-test has ever been run
 | SMART Selective self-test log data structure revision number 0
 | Note: revision number not 1 implies that no selective self-test has ever 
been run
 |  SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
 |     1        0        0  Completed [00% left] (0-65535)
 |     2        0        0  Not_testing
 |     3        0        0  Not_testing
 |     4        0        0  Not_testing
 |     5        0        0  Not_testing
 | Selective self-test flags (0x0):
 |   After scanning selected spans, do NOT read-scan remainder of disk.
 | If Selective self-test is pending on power-up, resume after 0 minute delay.



------------------------------------------------------------------------------
Storage Efficiency Calculator
This modeling tool is based on patent-pending intellectual property that
has been used successfully in hundreds of IBM storage optimization engage-
ments, worldwide.  Store less, Store more with what you own, Move data to 
the right place. Try It Now! http://www.accelacomm.com/jaw/sfnl/114/51427378/
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to