smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.0.4-atom1] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Device Model: SAMSUNG HM250HJ
Serial Number: S2ATJDNB311011
LU WWN Device Id: 5 0024e9 004cdf433
Firmware Version: 2AK10001
User Capacity: 250,059,350,016 bytes [250 GB]
Sector Size: 512 bytes logical/physical
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 8
ATA Standard is: ATA-8-ACS revision 6
Local Time is: Fri Oct 14 15:08:52 2011 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 3240) seconds.
Offline data collection
capabilities: (0x51) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 54) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 100 100 051 Pre-fail Always
- 0
2 Throughput_Performance 0x0027 252 252 000 Pre-fail Always
- 0
3 Spin_Up_Time 0x0023 090 090 025 Pre-fail Always
- 3211
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always
- 121
5 Reallocated_Sector_Ct 0x0033 252 252 010 Pre-fail Always
- 0
7 Seek_Error_Rate 0x002f 252 252 051 Pre-fail Always
- 0
8 Seek_Time_Performance 0x0025 252 252 015 Pre-fail Offline
- 0
9 Power_On_Hours 0x0032 100 100 000 Old_age Always
- 328
10 Spin_Retry_Count 0x0033 252 252 051 Pre-fail Always
- 0
11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always
- 135
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always
- 99
183 Runtime_Bad_Block 0x0032 252 252 010 Old_age Always
- 0
184 End-to-End_Error 0x0033 252 252 048 Pre-fail Always
- 0
186 Unknown_Attribute 0x0032 252 252 000 Old_age Always
- 0
187 Reported_Uncorrect 0x0032 252 252 000 Old_age Always
- 0
188 Command_Timeout 0x0032 252 252 000 Old_age Always
- 0
190 Airflow_Temperature_Cel 0x0002 061 055 040 Old_age Always
- 39 (Min/Max 20/45)
191 G-Sense_Error_Rate 0x0022 100 100 000 Old_age Always
- 185
192 Power-Off_Retract_Count 0x0022 252 252 000 Old_age Always
- 0
193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always
- 2767
194 Temperature_Celsius 0x0002 061 055 000 Old_age Always
- 39 (Min/Max 20/45)
195 Hardware_ECC_Recovered 0x003a 100 100 000 Old_age Always
- 0
196 Reallocated_Event_Count 0x0032 252 252 000 Old_age Always
- 0
197 Current_Pending_Sector 0x0032 252 252 000 Old_age Always
- 0
198 Offline_Uncorrectable 0x0030 252 252 000 Old_age Offline
- 0
199 UDMA_CRC_Error_Count 0x0036 200 200 000 Old_age Always
- 0
200 Multi_Zone_Error_Rate 0x002a 100 100 000 Old_age Always
- 24
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 328 -
# 2 Short offline Completed without error 00% 6 -
Note: selective self-test log revision number (0) not 1 implies that no
selective self-test has ever been run
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been
run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Completed [00% left] (0-65535)
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
All the data continuously generated in your IT infrastructure contains a
definitive record of customers, application performance, security
threats, fraudulent activity and more. Splunk takes this data and makes