Hi Christian, hi all,
the attached output shows strange Head_Flying_Hours for a ST3500418AS.
Should be near the POH of 69 hours.
Lenovo has issued a firmware update "Solution to abnormal bootup of Seagate hard
disk in low temperatures"
for this drive which updates drive firmware from f.e. CC66 to CC6B :
http://consumersupport.lenovo.com/ot/en/HintsandTips/hints_show_12986307218600.html
(Applies to ST3250318AS, ST3500418AS, ST3160318AS, ST3320418AS)
On Seagate's site itself the most recent firmware for that drive seems to be
CC49 :
http://seagate.custkb.com/seagate/crm/selfservice/search.jsp?DocId=213891&NewLang=en
Seems to follow established tradition (and I'm tired of searching now) in that
I could neither find a Changelog in the given link nor in the bootable CD ISO
image.
Greetings,
Frieder
smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.1.0-rc9-1-desktop] (SUSE RPM)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.12
Device Model: ST3500418AS
Serial Number: 9VMB4A8S
LU WWN Device Id: 5 000c50 02213a63c
Firmware Version: CC6B
User Capacity: 500.107.862.016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: 8
ATA Standard is: ATA-8-ACS revision 4
Local Time is: Tue Nov 1 17:44:56 2011 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 609) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 82) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x103f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 116 099 006 Pre-fail Always
- 109337400
3 Spin_Up_Time 0x0003 097 097 000 Pre-fail Always
- 0
4 Start_Stop_Count 0x0032 100 100 020 Old_age Always
- 230
5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always
- 0
7 Seek_Error_Rate 0x000f 062 060 030 Pre-fail Always
- 1799132
9 Power_On_Hours 0x0032 100 100 000 Old_age Always
- 69
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always
- 0
12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always
- 113
183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always
- 0
184 End-to-End_Error 0x0032 100 100 099 Old_age Always
- 0
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always
- 0
188 Command_Timeout 0x0032 100 100 000 Old_age Always
- 0
189 High_Fly_Writes 0x003a 100 100 000 Old_age Always
- 0
190 Airflow_Temperature_Cel 0x0022 079 052 045 Old_age Always
- 21 (Min/Max 18/21)
194 Temperature_Celsius 0x0022 021 048 000 Old_age Always
- 21 (0 15 0 0)
195 Hardware_ECC_Recovered 0x001a 043 036 000 Old_age Always
- 109337400
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always
- 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline
- 0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always
- 0
240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline
- 145582211465480
241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline
- 4127790000
242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline
- 298134757
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 24 -
# 2 Short offline Completed without error 00% 24 -
# 3 Short offline Completed without error 00% 3 -
# 4 Vendor (0x50) Completed without error 00% 2 -
# 5 Short offline Completed without error 00% 1 -
# 6 Vendor (0x50) Completed without error 00% 0 -
# 7 Extended offline Aborted by host 90% 0 -
# 8 Short offline Completed without error 00% 0 -
# 9 Vendor (0x50) Completed without error 00% 0 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
RSA® Conference 2012
Save $700 by Nov 18
Register now
http://p.sf.net/sfu/rsa-sfdev2dev1
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database