Using smartctl 5.42 it tolds me it is not in smartctl database

BTW: Those weird 6 Errors always existed on this disk, disk had already more 
than 96h runtime after  purchasing it
smartctl 5.42 2011-10-20 r3458 [x86_64-linux-3.1.2] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     WDC WD3000JD-98KLB0
Serial Number:    WD-WMAMR1578341
Firmware Version: 08.05J08
User Capacity:    300.069.052.416 bytes [300 GB]
Sector Size:      512 bytes logical/physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   6
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Mon Dec  5 01:51:03 2011 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x85) Offline data collection activity
                                        was aborted by an interrupting command 
from host.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                ( 9600) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        No General Purpose Logging support.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        ( 116) minutes.
Conveyance self-test routine
recommended polling time:        (   6) minutes.
SCT capabilities:              (0x001f) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   200   200   051    Pre-fail  Always       
-       0
  3 Spin_Up_Time            0x0003   205   188   021    Pre-fail  Always       
-       4733
  4 Start_Stop_Count        0x0032   099   099   000    Old_age   Always       
-       1296
  5 Reallocated_Sector_Ct   0x0033   200   200   140    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x000f   200   200   051    Pre-fail  Always       
-       0
  9 Power_On_Hours          0x0032   063   063   000    Old_age   Always       
-       27016
 10 Spin_Retry_Count        0x0013   100   100   051    Pre-fail  Always       
-       0
 11 Calibration_Retry_Count 0x0012   100   100   051    Old_age   Always       
-       0
 12 Power_Cycle_Count       0x0032   099   099   000    Old_age   Always       
-       1182
194 Temperature_Celsius     0x0022   115   093   000    Old_age   Always       
-       35
196 Reallocated_Event_Count 0x0032   200   200   000    Old_age   Always       
-       0
197 Current_Pending_Sector  0x0012   200   200   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0010   200   200   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       
-       0
200 Multi_Zone_Error_Rate   0x0009   200   199   051    Pre-fail  Offline      
-       0

SMART Error Log Version: 1
ATA Error Count: 6 (device log contains only the most recent five errors)
        CR = Command Register [HEX]
        FR = Features Register [HEX]
        SC = Sector Count Register [HEX]
        SN = Sector Number Register [HEX]
        CL = Cylinder Low Register [HEX]
        CH = Cylinder High Register [HEX]
        DH = Device/Head Register [HEX]
        DC = Device Command Register [HEX]
        ER = Error register [HEX]
        ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 6 occurred at disk power-on lifetime: 12 hours (0 days + 12 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 08 f7 3f 2e e0  Error: UNC 8 sectors at LBA = 0x002e3ff7 = 3031031

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 08 f7 3f 2e 06 68      12:49:51.375  READ DMA EXT
  25 00 00 f7 40 2e 06 68      12:49:51.285  READ DMA EXT
  25 00 00 a7 aa b7 06 68      12:49:51.270  READ DMA EXT
  25 00 f8 ff 3f 2e 06 68      12:49:51.225  READ DMA EXT
  25 00 00 f7 3f 2e 06 68      12:49:48.825  READ DMA EXT

Error 5 occurred at disk power-on lifetime: 12 hours (0 days + 12 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 f7 3f 2e e0  Error: UNC at LBA = 0x002e3ff7 = 3031031

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 00 f7 3f 2e 06 68      12:49:48.825  READ DMA EXT
  25 00 00 f7 3f 2e 06 68      12:49:46.800  READ DMA EXT
  25 00 00 f7 3f 2e 06 68      12:49:44.420  READ DMA EXT
  25 00 00 f7 3f 2e 06 68      12:49:42.025  READ DMA EXT
  25 00 00 f7 3f 2e 06 68      12:49:39.635  READ DMA EXT

Error 4 occurred at disk power-on lifetime: 12 hours (0 days + 12 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 f7 3f 2e e0  Error: UNC at LBA = 0x002e3ff7 = 3031031

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 00 f7 3f 2e 06 68      12:49:46.800  READ DMA EXT
  25 00 00 f7 3f 2e 06 68      12:49:44.420  READ DMA EXT
  25 00 00 f7 3f 2e 06 68      12:49:42.025  READ DMA EXT
  25 00 00 f7 3f 2e 06 68      12:49:39.635  READ DMA EXT
  25 00 60 8f 3f 2e 06 68      12:49:39.630  READ DMA EXT

Error 3 occurred at disk power-on lifetime: 12 hours (0 days + 12 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 f7 3f 2e e0  Error: UNC at LBA = 0x002e3ff7 = 3031031

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 00 f7 3f 2e 06 68      12:49:44.420  READ DMA EXT
  25 00 00 f7 3f 2e 06 68      12:49:42.025  READ DMA EXT
  25 00 00 f7 3f 2e 06 68      12:49:39.635  READ DMA EXT
  25 00 60 8f 3f 2e 06 68      12:49:39.630  READ DMA EXT
  25 00 00 a7 a8 b7 06 68      12:49:39.620  READ DMA EXT

Error 2 occurred at disk power-on lifetime: 12 hours (0 days + 12 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 f7 3f 2e e0  Error: UNC at LBA = 0x002e3ff7 = 3031031

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 00 f7 3f 2e 06 68      12:49:42.025  READ DMA EXT
  25 00 00 f7 3f 2e 06 68      12:49:39.635  READ DMA EXT
  25 00 60 8f 3f 2e 06 68      12:49:39.630  READ DMA EXT
  25 00 00 a7 a8 b7 06 68      12:49:39.620  READ DMA EXT
  25 00 08 ef 3f 2e 06 68      12:49:39.610  READ DMA EXT

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%     27016         -
# 2  Extended offline    Completed without error       00%     23138         -
# 3  Extended offline    Completed without error       00%     22594         -
# 4  Extended offline    Interrupted (host reset)      30%     22512         -
# 5  Extended offline    Completed without error       00%     18593         -
# 6  Extended offline    Completed without error       00%     13815         -
# 7  Extended offline    Completed without error       00%     11989         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

------------------------------------------------------------------------------
All the data continuously generated in your IT infrastructure 
contains a definitive record of customers, application performance, 
security threats, fraudulent activity, and more. Splunk takes this 
data and makes sense of it. IT sense. And common sense.
http://p.sf.net/sfu/splunk-novd2d
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to