smartctl 5.41 2011-04-06 r3314 [i386-apple-darwin9.8.0] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Model Family:     Apple SSD TS*
Device Model:     APPLE SSD TS128B
Serial Number:    60TS116IT4RZ
Firmware Version: AGAA0206
User Capacity:    121,332,826,112 bytes [121 GB]
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   8
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Fri Jan  6 13:18:59 2012 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                (  408) seconds.
Offline data collection
capabilities:                    (0x1b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        No Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  10) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000a   100   100   000    Old_age   Always       
-       0
  2 Throughput_Performance  0x0005   100   100   050    Pre-fail  Offline      
-       0
  3 Spin_Up_Time            0x0007   100   100   050    Pre-fail  Always       
-       0
  5 Reallocated_Sector_Ct   0x0013   100   100   050    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x000b   100   100   050    Pre-fail  Always       
-       0
  8 Seek_Time_Performance   0x0005   100   100   050    Pre-fail  Offline      
-       0
  9 Power_On_Hours          0x0012   100   100   000    Old_age   Always       
-       1478
 10 Unknown_Attribute       0x0013   100   100   050    Pre-fail  Always       
-       0
 12 Power_Cycle_Count       0x0012   100   100   000    Old_age   Always       
-       1826
167 Unknown_Attribute       0x0022   100   100   000    Old_age   Always       
-       0
168 Unknown_Attribute       0x0012   100   100   000    Old_age   Always       
-       0
169 Unknown_Attribute       0x0013   100   100   010    Pre-fail  Always       
-       768927465904
170 Unknown_Attribute       0x0013   100   100   010    Pre-fail  Always       
-       98793422946
171 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      
-       179
173 Unknown_Attribute       0x0013   199   199   100    Pre-fail  Always       
-       4297130005
175 Program_Fail_Count_Chip 0x0013   100   100   010    Pre-fail  Always       
-       0
192 Power-Off_Retract_Count 0x0012   100   100   000    Old_age   Always       
-       5
194 Temperature_Celsius     0x0023   073   062   030    Pre-fail  Always       
-       27 (Min/Max 9/38)
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       
-       0
199 UDMA_CRC_Error_Count    0x0012   100   100   000    Old_age   Always       
-       0
240 Unknown_Attribute       0x0013   100   100   050    Pre-fail  Always       
-       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Extended offline    Completed without error       00%      1478         -

Device does not support Selective Self Tests/Logging

------------------------------------------------------------------------------
Ridiculously easy VDI. With Citrix VDI-in-a-Box, you don't need a complex
infrastructure or vast IT resources to deliver seamless, secure access to
virtual desktops. With this all-in-one solution, easily deploy virtual 
desktops for less than the cost of PCs and save 60% on VDI infrastructure 
costs. Try it free! http://p.sf.net/sfu/Citrix-VDIinabox
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to