Can we add this model to the database?
Hitachi HDE721010SLA330

smartctl 5.42 2011-10-20 r3458 [x86_64-linux-2.6.38-gentoo-r6] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     Hitachi HDE721010SLA330
Serial Number:    STN604MH12PZMB
LU WWN Device Id: 5 000cca 349cf52c9
Firmware Version: ST6OA31B
User Capacity:    1,000,204,886,016 bytes [1.00 TB]
Sector Size:      512 bytes logical/physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Mon Jan  9 19:23:32 2012 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x85) Offline data collection activity
                                        was aborted by an interrupting command 
from host.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      ( 241) Self-test routine in progress...
                                        10% of test remaining.
Total time to complete Offline 
data collection:                (14090) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 235) minutes.
SCT capabilities:              (0x003d) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000b   100   100   016    Pre-fail  Always       
-       0
  2 Throughput_Performance  0x0005   100   100   054    Pre-fail  Offline      
-       0
  3 Spin_Up_Time            0x0007   121   121   024    Pre-fail  Always       
-       464 (Average 480)
  4 Start_Stop_Count        0x0012   100   100   000    Old_age   Always       
-       59
  5 Reallocated_Sector_Ct   0x0033   100   100   005    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x000b   100   100   067    Pre-fail  Always       
-       0
  8 Seek_Time_Performance   0x0005   125   125   020    Pre-fail  Offline      
-       33
  9 Power_On_Hours          0x0012   097   097   000    Old_age   Always       
-       21650
 10 Spin_Retry_Count        0x0013   100   100   060    Pre-fail  Always       
-       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       59
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       
-       806
193 Load_Cycle_Count        0x0012   100   100   000    Old_age   Always       
-       806
194 Temperature_Celsius     0x0002   130   130   000    Old_age   Always       
-       46 (Min/Max 20/53)
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       
-       0
197 Current_Pending_Sector  0x0022   100   100   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0008   100   100   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x000a   200   200   000    Old_age   Always       
-       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%     21638         -
# 2  Short offline       Completed without error       00%     21614         -
# 3  Short offline       Completed without error       00%     21590         -
# 4  Short offline       Completed without error       00%     21566         -
# 5  Short offline       Completed without error       00%     21542         -
# 6  Short offline       Completed without error       00%     21518         -
# 7  Short offline       Completed without error       00%     21494         -
# 8  Short offline       Completed without error       00%     21470         -
# 9  Extended offline    Completed without error       00%     21446         -
#10  Short offline       Completed without error       00%     21422         -
#11  Short offline       Completed without error       00%     21398         -
#12  Short offline       Completed without error       00%     21374         -
#13  Short offline       Completed without error       00%     21350         -
#14  Short offline       Completed without error       00%     21326         -
#15  Short offline       Completed without error       00%     21326         -
#16  Short offline       Completed without error       00%     21302         -
#17  Short offline       Completed without error       00%     21278         -
#18  Short offline       Completed without error       00%     21254         -
#19  Short offline       Completed without error       00%     21230         -
#20  Short offline       Completed without error       00%     21206         -
#21  Short offline       Completed without error       00%     21182         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

------------------------------------------------------------------------------
Write once. Port to many.
Get the SDK and tools to simplify cross-platform app development. Create 
new or port existing apps to sell to consumers worldwide. Explore the 
Intel AppUpSM program developer opportunity. appdeveloper.intel.com/join
http://p.sf.net/sfu/intel-appdev
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to