Hi,

This USB external HD works with smartctl, but currently (version 5.41)
requires the "-d sat" option to work. Information:

####

$ sudo smartctl -d sat -q noserial -a /dev/sdc
smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.0.0-16-generic] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Model Family:     SAMSUNG SpinPoint F2 EG
Device Model:     SAMSUNG HD103SI
Firmware Version: 1AG01118
User Capacity:    1,000,204,886,016 bytes [1.00 TB]
Sector Size:      512 bytes logical/physical
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 3b
Local Time is:    Sat Feb 25 10:49:11 2012 AMT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00)    Offline data collection activity
                    was never started.
                    Auto Offline Data Collection: Disabled.
Self-test execution status:      ( 249)    Self-test routine in progress...
                    90% of test remaining.
Total time to complete Offline
data collection:         (12999) seconds.
Offline data collection
capabilities:              (0x7b) SMART execute Offline immediate.
                    Auto Offline data collection on/off support.
                    Suspend Offline collection upon new
                    command.
                    Offline surface scan supported.
                    Self-test supported.
                    Conveyance Self-test supported.
                    Selective Self-test supported.
SMART capabilities:            (0x0003)    Saves SMART data before entering
                    power-saving mode.
                    Supports SMART auto save timer.
Error logging capability:        (0x01)    Error logging supported.
                    General Purpose Logging supported.
Short self-test routine
recommended polling time:      (   2) minutes.
Extended self-test routine
recommended polling time:      ( 217) minutes.
Conveyance self-test routine
recommended polling time:      (  23) minutes.
SCT capabilities:            (0x003f)    SCT Status supported.
                    SCT Error Recovery Control supported.
                    SCT Feature Control supported.
                    SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   100   100   051    Pre-fail
Always       -       0
  3 Spin_Up_Time            0x0007   083   083   011    Pre-fail
Always       -       6110
  4 Start_Stop_Count        0x0032   100   100   000    Old_age
Always       -       286
  5 Reallocated_Sector_Ct   0x0033   100   100   010    Pre-fail
Always       -       0
  7 Seek_Error_Rate         0x000f   253   253   051    Pre-fail
Always       -       0
  8 Seek_Time_Performance   0x0025   100   100   015    Pre-fail
Offline      -       12779
  9 Power_On_Hours          0x0032   100   100   000    Old_age
Always       -       267
 10 Spin_Retry_Count        0x0033   100   100   051    Pre-fail
Always       -       0
 11 Calibration_Retry_Count 0x0012   100   100   000    Old_age
Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age
Always       -       76
 13 Read_Soft_Error_Rate    0x000e   100   100   000    Old_age
Always       -       0
183 Runtime_Bad_Block       0x0032   100   100   000    Old_age
Always       -       0
184 End-to-End_Error        0x0033   100   100   000    Pre-fail
Always       -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age
Always       -       0
188 Command_Timeout         0x0032   100   100   000    Old_age
Always       -       0
190 Airflow_Temperature_Cel 0x0022   063   055   000    Old_age
Always       -       37 (Min/Max 20/37)
194 Temperature_Celsius     0x0022   056   052   000    Old_age
Always       -       44 (Min/Max 20/44)
195 Hardware_ECC_Recovered  0x001a   100   100   000    Old_age
Always       -       43155203
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age
Always       -       0
197 Current_Pending_Sector  0x0012   100   100   000    Old_age
Always       -       0
198 Offline_Uncorrectable   0x0030   100   100   000    Old_age
Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   100   100   000    Old_age
Always       -       0
200 Multi_Zone_Error_Rate   0x000a   100   100   000    Old_age
Always       -       0
201 Soft_Read_Error_Rate    0x000a   100   100   000    Old_age
Always       -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining
LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Self-test routine in progress 90%
267         -
# 2  Short offline       Aborted by host               60%
0         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

####

$ sudo lsusb -d 04e8:5f05 -v

Bus 001 Device 003: ID 04e8:5f05 Samsung Electronics Co., Ltd
Device Descriptor:
  bLength                18
  bDescriptorType         1
  bcdUSB               2.00
  bDeviceClass            0 (Defined at Interface level)
  bDeviceSubClass         0
  bDeviceProtocol         0
  bMaxPacketSize0        64
  idVendor           0x04e8 Samsung Electronics Co., Ltd
  idProduct          0x5f05
  bcdDevice            0.00
  iManufacturer           1 JMicron
  iProduct               11 Samsung STORY Station
  iSerial                 3 [...]
  bNumConfigurations      1
  Configuration Descriptor:
    bLength                 9
    bDescriptorType         2
    wTotalLength           32
    bNumInterfaces          1
    bConfigurationValue     1
    iConfiguration          4 USB Mass Storage
    bmAttributes         0xc0
      Self Powered
    MaxPower                2mA
    Interface Descriptor:
      bLength                 9
      bDescriptorType         4
      bInterfaceNumber        0
      bAlternateSetting       0
      bNumEndpoints           2
      bInterfaceClass         8 Mass Storage
      bInterfaceSubClass      6 SCSI
      bInterfaceProtocol     80 Bulk (Zip)
      iInterface              6 MSC Bulk-Only Transfer
      Endpoint Descriptor:
        bLength                 7
        bDescriptorType         5
        bEndpointAddress     0x81  EP 1 IN
        bmAttributes            2
          Transfer Type            Bulk
          Synch Type               None
          Usage Type               Data
        wMaxPacketSize     0x0200  1x 512 bytes
        bInterval               0
      Endpoint Descriptor:
        bLength                 7
        bDescriptorType         5
        bEndpointAddress     0x02  EP 2 OUT
        bmAttributes            2
          Transfer Type            Bulk
          Synch Type               None
          Usage Type               Data
        wMaxPacketSize     0x0200  1x 512 bytes
        bInterval               0
Device Qualifier (for other device speed):
  bLength                10
  bDescriptorType         6
  bcdUSB               2.00
  bDeviceClass            0 (Defined at Interface level)
  bDeviceSubClass         0
  bDeviceProtocol         0
  bMaxPacketSize0        64
  bNumConfigurations      1
Device Status:     0x0001
  Self Powered

####

Best Regards
-- 
Anderson Lizardo
------------------------------------------------------------------------------
Virtualization & Cloud Management Using Capacity Planning
Cloud computing makes use of virtualization - but cloud computing 
also focuses on allowing computing to be delivered as a service.
http://www.accelacomm.com/jaw/sfnl/114/51521223/
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to