smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.2.0-2-amd64] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     ST3000DM001-9YN166
Serial Number:    Z1F0HPS1
LU WWN Device Id: 5 000c50 03fe125f4
Firmware Version: CC4C
User Capacity:    3,000,592,982,016 bytes [3.00 TB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Fri Mar 23 20:46:20 2012 CDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                (  584) seconds.
Offline data collection
capabilities:                    (0x73) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        No Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 255) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x3085) SCT Status supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   100   100   006    Pre-fail  Always       
-       53792
  3 Spin_Up_Time            0x0003   098   098   000    Pre-fail  Always       
-       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       
-       2
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x000f   100   253   030    Pre-fail  Always       
-       133188
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       
-       0
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       
-       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       
-       2
183 Runtime_Bad_Block       0x0032   100   100   000    Old_age   Always       
-       0
184 End-to-End_Error        0x0032   100   100   099    Old_age   Always       
-       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       
-       0
188 Command_Timeout         0x0032   100   100   000    Old_age   Always       
-       0
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       
-       0
190 Airflow_Temperature_Cel 0x0022   058   058   045    Old_age   Always       
-       42 (Min/Max 32/42)
191 G-Sense_Error_Rate      0x0032   100   100   000    Old_age   Always       
-       0
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       
-       1
193 Load_Cycle_Count        0x0032   100   100   000    Old_age   Always       
-       4
194 Temperature_Celsius     0x0022   042   042   000    Old_age   Always       
-       42 (0 27 0 0)
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       
-       0
240 Head_Flying_Hours       0x0000   100   253   000    Old_age   Offline      
-       147085450018816
241 Total_LBAs_Written      0x0000   100   253   000    Old_age   Offline      
-       42743640287800
242 Total_LBAs_Read         0x0000   100   253   000    Old_age   Offline      
-       4639

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%         0         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

------------------------------------------------------------------------------
This SF email is sponsosred by:
Try Windows Azure free for 90 days Click Here 
http://p.sf.net/sfu/sfd2d-msazure
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to