This is a new 1Tb drive .. seems to work re; tests but the counters seem to be 
all wrong ... 


Using latest smartmontools DB (5.42) with smartmontools 5.41. 

-- 


smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.2.0-21-generic] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     ST1000DM003-9YN162
Serial Number:    Z1D08J1A
LU WWN Device Id: 5 000c50 03f4b39e3
Firmware Version: CC46
User Capacity:    1,000,204,886,016 bytes [1.00 TB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Sat Jun  2 14:35:01 2012 BST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                (  575) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 113) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x3085) SCT Status supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   109   100   006    Pre-fail  Always       
-       21872688
  3 Spin_Up_Time            0x0003   097   097   000    Pre-fail  Always       
-       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       
-       34
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x000f   100   253   030    Pre-fail  Always       
-       4295027427
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       
-       340
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       
-       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       
-       34
183 Runtime_Bad_Block       0x0032   100   100   000    Old_age   Always       
-       0
184 End-to-End_Error        0x0032   100   100   099    Old_age   Always       
-       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       
-       0
188 Command_Timeout         0x0032   100   100   000    Old_age   Always       
-       0
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       
-       0
190 Airflow_Temperature_Cel 0x0022   076   071   045    Old_age   Always       
-       24 (Min/Max 14/29)
191 G-Sense_Error_Rate      0x0032   100   100   000    Old_age   Always       
-       0
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       
-       32
193 Load_Cycle_Count        0x0032   100   100   000    Old_age   Always       
-       38
194 Temperature_Celsius     0x0022   024   040   000    Old_age   Always       
-       24 (0 14 0 0)
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       
-       0
240 Head_Flying_Hours       0x0000   100   253   000    Old_age   Offline      
-       261722422116692
241 Total_LBAs_Written      0x0000   100   253   000    Old_age   Offline      
-       489631913793
242 Total_LBAs_Read         0x0000   100   253   000    Old_age   Offline      
-       403720481566

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%       340         -
# 2  Short offline       Aborted by host               80%       340         -
# 3  Extended offline    Completed without error       00%       184         -
# 4  Extended offline    Completed without error       00%        57         -
# 5  Extended offline    Completed without error       00%         1         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

------------------------------------------------------------------------------
Live Security Virtual Conference
Exclusive live event will cover all the ways today's security and 
threat landscape has changed and how IT managers can respond. Discussions 
will include endpoint security, mobile security and the latest in malware 
threats. http://www.accelacomm.com/jaw/sfrnl04242012/114/50122263/
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to