Cause this device was not found in smartmontools 5.42, here is the new file.

U.
smartctl 5.42 2011-10-20 r3458 [x86_64-linux-2.6.38-15-generic] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     SanDisk SDSSDP064G
Serial Number:    121978403145
LU WWN Device Id: 5 001b44 7720fb549
Firmware Version: 1.0.0
User Capacity:    64.023.257.088 bytes [64,0 GB]
Sector Size:      512 bytes logical/physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ACS-2 revision 3
Local Time is:    Fri Jun  8 11:21:56 2012 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                (  120) seconds.
Offline data collection
capabilities:                    (0x51) SMART execute Offline immediate.
                                        No Auto Offline data collection support.
                                        Suspend Offline collection upon new
                                        command.
                                        No Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  12) minutes.

SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  5 Reallocated_Sector_Ct   0x0002   100   100   000    Old_age   Always       
-       0
  9 Power_On_Hours          0x0002   100   100   000    Old_age   Always       
-       0
 12 Power_Cycle_Count       0x0002   100   100   000    Old_age   Always       
-       3
171 Unknown_Attribute       0x0002   100   100   000    Old_age   Always       
-       0
172 Unknown_Attribute       0x0002   100   100   000    Old_age   Always       
-       0
173 Unknown_Attribute       0x0002   100   100   000    Old_age   Always       
-       0
174 Unknown_Attribute       0x0002   100   100   000    Old_age   Always       
-       0
187 Reported_Uncorrect      0x0002   100   100   000    Old_age   Always       
-       0
230 Head_Amplitude          0x0002   100   100   000    Old_age   Always       
-       0
232 Available_Reservd_Space 0x0003   100   100   005    Pre-fail  Always       
-       0
234 Unknown_Attribute       0x0002   100   100   000    Old_age   Always       
-       0
241 Total_LBAs_Written      0x0002   100   100   000    Old_age   Always       
-       0
242 Total_LBAs_Read         0x0002   100   100   000    Old_age   Always       
-       1410

SMART Error Log Version: 1
No Errors Logged

Warning! SMART Self-Test Log Structure error: invalid SMART checksum.
SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%         0         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

------------------------------------------------------------------------------
Live Security Virtual Conference
Exclusive live event will cover all the ways today's security and 
threat landscape has changed and how IT managers can respond. Discussions 
will include endpoint security, mobile security and the latest in malware 
threats. http://www.accelacomm.com/jaw/sfrnl04242012/114/50122263/
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database