smartctl 6.1 2012-11-04 r3673 [x86_64-linux-3.4.11-2.16-desktop] (local build)
Copyright (C) 2002-12, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: SanDisk SDSSDP064G
Serial Number: 121876405294
LU WWN Device Id: 5 001b44 76bfb582e
Firmware Version: 1.0.0
User Capacity: 64,023,257,088 bytes [64.0 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 1.5 Gb/s)
Local Time is: Thu Nov 8 14:20:19 2012 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, frozen [SEC2]
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 25) The self-test routine was aborted by
the host.
Total time to complete Offline
data collection: ( 120) seconds.
Offline data collection
capabilities: (0x51) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 12) minutes.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct -O---- 100 100 000 - 0
9 Power_On_Hours -O---- 100 100 000 - 1371
12 Power_Cycle_Count -O---- 100 100 000 - 6
171 Unknown_Attribute -O---- 100 100 000 - 0
172 Unknown_Attribute -O---- 100 100 000 - 0
173 Unknown_Attribute -O---- 100 100 000 - 0
174 Unknown_Attribute -O---- 100 100 000 - 2
187 Reported_Uncorrect -O---- 100 100 000 - 0
230 Unknown_SSD_Attribute -O---- 100 100 000 - 0
232 Available_Reservd_Space PO---- 100 100 005 - 0
234 Unknown_Attribute -O---- 100 100 000 - 2
241 Total_LBAs_Written -O---- 100 100 000 - 104358736
242 Total_LBAs_Read -O---- 100 100 000 - 92077614
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
ATA_READ_LOG_EXT (addr=0x00:0x00, page=0, n=1) failed: 48-bit ATA commands not
implemented
Read GP Log Directory failed
SMART Log Directory Version 1 [multi-sector log support]
SMART Log at address 0x00 has 1 sectors [Log Directory]
SMART Log at address 0x01 has 1 sectors [Summary SMART error log]
SMART Log at address 0x03 has 16 sectors [Ext. Comprehensive SMART error log]
SMART Log at address 0x04 has 8 sectors [Device Statistics log]
SMART Log at address 0x06 has 1 sectors [SMART self-test log]
SMART Log at address 0x10 has 1 sectors [NCQ Command Error log]
SMART Log at address 0x11 has 1 sectors [SATA Phy Event Counters]
SMART Log at address 0x30 has 9 sectors [IDENTIFY DEVICE data log]
SMART Log at address 0x80 has 16 sectors [Host vendor specific log]
SMART Log at address 0x81 has 16 sectors [Host vendor specific log]
SMART Log at address 0x82 has 16 sectors [Host vendor specific log]
SMART Log at address 0x83 has 16 sectors [Host vendor specific log]
SMART Log at address 0x84 has 16 sectors [Host vendor specific log]
SMART Log at address 0x85 has 16 sectors [Host vendor specific log]
SMART Log at address 0x86 has 16 sectors [Host vendor specific log]
SMART Log at address 0x87 has 16 sectors [Host vendor specific log]
SMART Log at address 0x88 has 16 sectors [Host vendor specific log]
SMART Log at address 0x89 has 16 sectors [Host vendor specific log]
SMART Log at address 0x8a has 16 sectors [Host vendor specific log]
SMART Log at address 0x8b has 16 sectors [Host vendor specific log]
SMART Log at address 0x8c has 16 sectors [Host vendor specific log]
SMART Log at address 0x8d has 16 sectors [Host vendor specific log]
SMART Log at address 0x8e has 16 sectors [Host vendor specific log]
SMART Log at address 0x8f has 16 sectors [Host vendor specific log]
SMART Log at address 0x90 has 16 sectors [Host vendor specific log]
SMART Log at address 0x91 has 16 sectors [Host vendor specific log]
SMART Log at address 0x92 has 16 sectors [Host vendor specific log]
SMART Log at address 0x93 has 16 sectors [Host vendor specific log]
SMART Log at address 0x94 has 16 sectors [Host vendor specific log]
SMART Log at address 0x95 has 16 sectors [Host vendor specific log]
SMART Log at address 0x96 has 16 sectors [Host vendor specific log]
SMART Log at address 0x97 has 16 sectors [Host vendor specific log]
SMART Log at address 0x98 has 16 sectors [Host vendor specific log]
SMART Log at address 0x99 has 16 sectors [Host vendor specific log]
SMART Log at address 0x9a has 16 sectors [Host vendor specific log]
SMART Log at address 0x9b has 16 sectors [Host vendor specific log]
SMART Log at address 0x9c has 16 sectors [Host vendor specific log]
SMART Log at address 0x9d has 16 sectors [Host vendor specific log]
SMART Log at address 0x9e has 16 sectors [Host vendor specific log]
SMART Log at address 0x9f has 16 sectors [Host vendor specific log]
SMART Log at address 0xa1 has 1 sectors [Device vendor specific log]
SMART Log at address 0xa2 has 2 sectors [Device vendor specific log]
SMART Log at address 0xa3 has 1 sectors [Device vendor specific log]
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log Version: 1
No Errors Logged
SMART Extended Self-test Log (GP Log 0x07) not supported
Warning! SMART Self-Test Log Structure error: invalid SMART checksum.
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Extended offline Aborted by host 90% 1371 -
# 2 Short offline Aborted by host 90% 155 -
# 3 Extended offline Aborted by host 90% 154 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP Log 0x04) not supported
ATA_READ_LOG_EXT (addr=0x11:0x00, page=0, n=1) failed: 48-bit ATA commands not
implemented
Read SATA Phy Event Counters failed
------------------------------------------------------------------------------
Everyone hates slow websites. So do we.
Make your web apps faster with AppDynamics
Download AppDynamics Lite for free today:
http://p.sf.net/sfu/appdyn_d2d_nov
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database