Samsung SpinPoint P80 SP0401N with firmware TJ100-30 requires -v
9,halfminutes, don't know about -v 198,increasing as there are no
failures but the drive should probably get added here:

 { "SAMSUNG SpinPoint P80", // firmware *-25...34, tested with
SP1614C/SW100-25 and -34
            "SAMSUNG SP(0451|08[0124]2|12[0145]3|16[0145]4)[CN]",
            ".*-(2[5-9]|3[0-4])",
            "",
            "-v 9,halfminutes -v 198,increasing"
 }
root@ubuntu:/home/ubuntu/smartmontools-5.43# ./smartctl -a /dev/sda
smartctl 5.43 2012-06-30 r3573 [i686-linux-2.6.35-22-generic] (local build)
Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     SAMSUNG SP0401N
Serial Number:    S004J10Y92XXXX (redacted for privacy reasons)
Firmware Version: TJ100-30
User Capacity:    40,060,403,712 bytes [40.0 GB]
Sector Size:      512 bytes logical/physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   7
ATA Standard is:  ATA/ATAPI-7 T13 1532D revision 0
Local Time is:    Mon Jul  2 11:32:01 2012 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x80) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                ( 1500) seconds.
Offline data collection
capabilities:                    (0x1b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        No Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        No General Purpose Logging support.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (  25) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   100   100   051    Pre-fail  Always       
-       0
  3 Spin_Up_Time            0x0007   100   100   025    Pre-fail  Always       
-       6208
  4 Start_Stop_Count        0x0032   094   094   000    Old_age   Always       
-       6587
  5 Reallocated_Sector_Ct   0x0033   100   100   011    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x000f   100   100   051    Pre-fail  Always       
-       0
  8 Seek_Time_Performance   0x0025   100   100   015    Pre-fail  Offline      
-       0
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       
-       367131
 10 Spin_Retry_Count        0x0033   100   100   051    Pre-fail  Always       
-       0
 11 Calibration_Retry_Count 0x0012   100   100   000    Old_age   Always       
-       0
 12 Power_Cycle_Count       0x0032   097   097   000    Old_age   Always       
-       3341
194 Temperature_Celsius     0x0022   130   085   000    Old_age   Always       
-       36
195 Hardware_ECC_Recovered  0x001a   100   100   000    Old_age   Always       
-       393373
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       
-       0
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0030   100   100   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       
-       0
200 Multi_Zone_Error_Rate   0x000a   100   100   051    Old_age   Always       
-       0
201 Soft_Read_Error_Rate    0x000a   100   100   051    Old_age   Always       
-       0

SMART Error Log Version: 1
ATA Error Count: 3
        CR = Command Register [HEX]
        FR = Features Register [HEX]
        SC = Sector Count Register [HEX]
        SN = Sector Number Register [HEX]
        CL = Cylinder Low Register [HEX]
        CH = Cylinder High Register [HEX]
        DH = Device/Head Register [HEX]
        DC = Device Command Register [HEX]
        ER = Error register [HEX]
        ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 3 occurred at disk power-on lifetime: 3057 hours (127 days + 9 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  04 51 fe 00 00 00 40  Error: ABRT

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  ef 05 fe 00 00 00 40 00      00:01:35.063  SET FEATURES [Enable APM]
  ec 00 01 00 00 00 00 00      00:01:34.063  IDENTIFY DEVICE
  c8 00 08 00 00 00 e0 00      00:01:33.688  READ DMA
  c8 00 08 00 10 00 e0 00      00:01:33.313  READ DMA
  c8 00 08 20 00 00 e0 00      00:01:33.313  READ DMA

Error 2 occurred at disk power-on lifetime: 3057 hours (127 days + 9 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  04 51 fe 00 00 00 40  Error: ABRT

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  ef 05 fe 00 00 00 40 00      00:16:24.625  SET FEATURES [Enable APM]
  ec 00 01 00 00 00 00 00      00:16:23.125  IDENTIFY DEVICE
  c8 00 08 00 00 00 e0 00      00:16:22.938  READ DMA
  c8 00 08 00 10 00 e0 00      00:16:22.438  READ DMA
  c8 00 08 20 00 00 e0 00      00:16:22.438  READ DMA

Error 1 occurred at disk power-on lifetime: 3056 hours (127 days + 8 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  04 51 fe 00 00 00 40  Error: ABRT

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  ef 05 fe 00 00 00 40 00      00:12:25.063  SET FEATURES [Enable APM]
  ec 00 01 00 00 00 00 00      00:12:23.875  IDENTIFY DEVICE
  c8 00 08 00 00 00 e0 00      00:12:23.438  READ DMA
  c8 00 08 00 10 00 e0 00      00:12:23.000  READ DMA
  c8 00 08 20 00 00 e0 00      00:12:23.000  READ DMA

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%      3059         -
# 2  Short offline       Completed without error       00%      3047         -

Device does not support Selective Self Tests/Logging
------------------------------------------------------------------------------
LogMeIn Rescue: Anywhere, Anytime Remote support for IT. Free Trial
Remotely access PCs and mobile devices and provide instant support
Improve your efficiency, and focus on delivering more value-add services
Discover what IT Professionals Know. Rescue delivers
http://p.sf.net/sfu/logmein_12329d2d
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to