Please find attached a submission for the disk TOSHIBA MK3265GSXN
smartctl 6.0 2012-10-10 r3643 [i686-w64-mingw32-win7] (sf-6.0-1)
Copyright (C) 2002-12, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: TOSHIBA MK3265GSXN
Serial Number: 41HYT03LT
LU WWN Device Id: 5 000039 332085fbe
Firmware Version: GH012H
User Capacity: 320,072,933,376 bytes [320 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 5400 rpm
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Thu Dec 13 13:45:56 2012 PST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 120) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 96) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always
- 0
2 Throughput_Performance 0x0005 100 100 050 Pre-fail Offline
- 0
3 Spin_Up_Time 0x0027 100 100 001 Pre-fail Always
- 1186
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always
- 477
5 Reallocated_Sector_Ct 0x0033 100 100 050 Pre-fail Always
- 12
7 Seek_Error_Rate 0x000b 100 100 050 Pre-fail Always
- 0
8 Seek_Time_Performance 0x0005 100 100 050 Pre-fail Offline
- 0
9 Power_On_Hours 0x0032 099 099 000 Old_age Always
- 661
10 Spin_Retry_Count 0x0033 109 100 030 Pre-fail Always
- 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always
- 477
191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always
- 79
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always
- 13
193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always
- 7424
194 Temperature_Celsius 0x0022 100 100 000 Old_age Always
- 25 (Min/Max 15/44)
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always
- 2
197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always
- 0
198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline
- 0
199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always
- 0
220 Disk_Shift 0x0002 100 100 000 Old_age Always
- 37
222 Loaded_Hours 0x0032 099 099 000 Old_age Always
- 424
223 Load_Retry_Count 0x0032 100 100 000 Old_age Always
- 0
224 Load_Friction 0x0022 100 100 000 Old_age Always
- 0
226 Load-in_Time 0x0026 100 100 000 Old_age Always
- 316
240 Head_Flying_Hours 0x0001 100 100 001 Pre-fail Offline
- 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 661 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
LogMeIn Rescue: Anywhere, Anytime Remote support for IT. Free Trial
Remotely access PCs and mobile devices and provide instant support
Improve your efficiency, and focus on delivering more value-add services
Discover what IT Professionals Know. Rescue delivers
http://p.sf.net/sfu/logmein_12329d2d
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database