smartctl 5.40 2010-10-16 r3189 [i386--netbsdelf] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Device Model: SAMSUNG HD103UI
Serial Number: S1LMJ1KQB00773
Firmware Version: 1AA01113
User Capacity: 1,000,204,886,016 bytes
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 8
ATA Standard is: ATA-8-ACS revision 3b
Local Time is: Wed Jan 2 02:47:45 2013 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (14590) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 244) minutes.
Conveyance self-test routine
recommended polling time: ( 26) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 100 100 051 Pre-fail Always
- 0
3 Spin_Up_Time 0x0007 064 064 011 Pre-fail Always
- 11400
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always
- 28
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always
- 0
7 Seek_Error_Rate 0x000f 253 253 051 Pre-fail Always
- 0
8 Seek_Time_Performance 0x0025 100 100 015 Pre-fail Offline
- 11919
9 Power_On_Hours 0x0032 098 098 000 Old_age Always
- 11968
10 Spin_Retry_Count 0x0033 100 100 051 Pre-fail Always
- 0
11 Calibration_Retry_Count 0x0012 100 100 000 Old_age Always
- 1
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always
- 28
13 Read_Soft_Error_Rate 0x000e 100 100 000 Old_age Always
- 0
183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always
- 0
184 End-to-End_Error 0x0033 100 100 000 Pre-fail Always
- 0
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always
- 0
188 Command_Timeout 0x0032 100 100 000 Old_age Always
- 0
190 Airflow_Temperature_Cel 0x0022 074 070 000 Old_age Always
- 26 (Min/Max 17/30)
194 Temperature_Celsius 0x0022 073 069 000 Old_age Always
- 27 (Min/Max 17/31)
195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always
- 127730549
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always
- 0
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always
- 0
198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline
- 0
199 UDMA_CRC_Error_Count 0x003e 100 100 000 Old_age Always
- 0
200 Multi_Zone_Error_Rate 0x000a 100 100 000 Old_age Always
- 0
201 Soft_Read_Error_Rate 0x000a 100 100 000 Old_age Always
- 0
General Purpose Logging (GPL) feature set supported
ATA_READ_LOG_EXT (addr=0x00:0x00, page=0, n=1) failed: 48-bit ATA commands not
supported
Read GP Log Directory failed.
SMART Log Directory Version 1 [multi-sector log support]
SMART Log at address 0x00 has 1 sectors [Log Directory]
SMART Log at address 0x01 has 1 sectors [Summary SMART error log]
SMART Log at address 0x02 has 2 sectors [Comprehensive SMART error log]
SMART Log at address 0x06 has 1 sectors [SMART self-test log]
SMART Log at address 0x09 has 1 sectors [Selective self-test log]
SMART Log at address 0x80 has 16 sectors [Host vendor specific log]
SMART Log at address 0x81 has 16 sectors [Host vendor specific log]
SMART Log at address 0x82 has 16 sectors [Host vendor specific log]
SMART Log at address 0x83 has 16 sectors [Host vendor specific log]
SMART Log at address 0x84 has 16 sectors [Host vendor specific log]
SMART Log at address 0x85 has 16 sectors [Host vendor specific log]
SMART Log at address 0x86 has 16 sectors [Host vendor specific log]
SMART Log at address 0x87 has 16 sectors [Host vendor specific log]
SMART Log at address 0x88 has 16 sectors [Host vendor specific log]
SMART Log at address 0x89 has 16 sectors [Host vendor specific log]
SMART Log at address 0x8a has 16 sectors [Host vendor specific log]
SMART Log at address 0x8b has 16 sectors [Host vendor specific log]
SMART Log at address 0x8c has 16 sectors [Host vendor specific log]
SMART Log at address 0x8d has 16 sectors [Host vendor specific log]
SMART Log at address 0x8e has 16 sectors [Host vendor specific log]
SMART Log at address 0x8f has 16 sectors [Host vendor specific log]
SMART Log at address 0x90 has 16 sectors [Host vendor specific log]
SMART Log at address 0x91 has 16 sectors [Host vendor specific log]
SMART Log at address 0x92 has 16 sectors [Host vendor specific log]
SMART Log at address 0x93 has 16 sectors [Host vendor specific log]
SMART Log at address 0x94 has 16 sectors [Host vendor specific log]
SMART Log at address 0x95 has 16 sectors [Host vendor specific log]
SMART Log at address 0x96 has 16 sectors [Host vendor specific log]
SMART Log at address 0x97 has 16 sectors [Host vendor specific log]
SMART Log at address 0x98 has 16 sectors [Host vendor specific log]
SMART Log at address 0x99 has 16 sectors [Host vendor specific log]
SMART Log at address 0x9a has 16 sectors [Host vendor specific log]
SMART Log at address 0x9b has 16 sectors [Host vendor specific log]
SMART Log at address 0x9c has 16 sectors [Host vendor specific log]
SMART Log at address 0x9d has 16 sectors [Host vendor specific log]
SMART Log at address 0x9e has 16 sectors [Host vendor specific log]
SMART Log at address 0x9f has 16 sectors [Host vendor specific log]
SMART Log at address 0xe0 has 1 sectors [SCT Command/Status]
SMART Log at address 0xe1 has 1 sectors [SCT Data Transfer]
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log Version: 1
No Errors Logged
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 11968 -
# 2 Short offline Completed without error 00% 11943 -
# 3 Short offline Completed without error 00% 11919 -
# 4 Short offline Completed without error 00% 11895 -
# 5 Extended offline Completed without error 00% 11876 -
# 6 Short offline Completed without error 00% 11871 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 256 (0x0100)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: 27 Celsius
Power Cycle Max Temperature: 31 Celsius
Lifetime Max Temperature: 41 Celsius
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: -4/72 Celsius
Min/Max Temperature Limit: -9/77 Celsius
Temperature History Size (Index): 128 (60)
Index Estimated Time Temperature Celsius
61 2013-01-02 00:40 26 *******
... ..(116 skipped). .. *******
50 2013-01-02 02:37 26 *******
51 2013-01-02 02:38 27 ********
... ..( 8 skipped). .. ********
60 2013-01-02 02:47 27 ********
Error SMART WRITE LOG does not return COUNT and LBA_LOW register
Warning: device does not support SCT (Get) Error Recovery Control command
SATA Phy Event Counters (GP Log 0x11) not supported
------------------------------------------------------------------------------
Master Visual Studio, SharePoint, SQL, ASP.NET, C# 2012, HTML5, CSS,
MVC, Windows 8 Apps, JavaScript and much more. Keep your skills current
with LearnDevNow - 3,200 step-by-step video tutorials by Microsoft
MVPs and experts. ON SALE this month only -- learn more at:
http://p.sf.net/sfu/learnmore_122712
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database