--
Regards,
Mus
smartctl 5.43 2012-06-30 r3573 [x86_64-linux-3.6.11-1.fc17.x86_64] (local build)
Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Device Model: KINGSTON SH103S3120G
Serial Number: 50026B722601DFDD
LU WWN Device Id: 5 0026b7 22601dfdd
Firmware Version: 501ABBF0
User Capacity: 120,034,123,776 bytes [120 GB]
Sector Size: 512 bytes logical/physical
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 8
ATA Standard is: ACS-2 revision 3
Local Time is: Mon Jan 7 08:01:46 2013 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Disabled
Write cache is: Enabled
ATA Security is: Disabled, NOT FROZEN [SEC1]
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x02) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 48) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x0001) SCT Status supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 120 120 050 - 0
5 Reallocated_Sector_Ct PO--CK 100 100 003 - 0
9 Power_On_Hours -O--CK 000 000 000 - 2792 (154 74 0)
12 Power_Cycle_Count -O--CK 100 100 000 - 66
171 Unknown_Attribute -O--CK 000 000 000 - 0
172 Unknown_Attribute -O--CK 000 000 000 - 0
174 Unknown_Attribute ----CK 000 000 000 - 20
177 Wear_Leveling_Count ------ 000 000 000 - 1
181 Program_Fail_Cnt_Total -O--CK 000 000 000 - 0
182 Erase_Fail_Count_Total -O--CK 000 000 000 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
194 Temperature_Celsius -O---K 030 078 000 - 30 (Min/Max 12/78)
195 Hardware_ECC_Recovered --SRC- 100 100 000 - 0
196 Reallocated_Event_Count PO--CK 100 100 003 - 0
201 Soft_Read_Error_Rate --SRC- 100 100 000 - 0
204 Soft_ECC_Correction --SRC- 100 100 000 - 0
230 Head_Amplitude PO--C- 100 100 000 - 100
231 Temperature_Celsius PO--C- 100 100 010 - 0
233 Media_Wearout_Indicator ------ 000 000 000 - 651
234 Unknown_Attribute -O--CK 000 000 000 - 441
241 Total_LBAs_Written -O--CK 000 000 000 - 441
242 Total_LBAs_Read -O--CK 000 000 000 - 350
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 0
SMART Log Directory Version 0
GP/S Log at address 0x00 has 1 sectors [Log Directory]
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log not supported
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test Log not supported
Note: selective self-test log revision number (0) not 1 implies that no
selective self-test has ever been run
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been
run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
Warning: device does not support SCT Data Table command
Warning: device does not support SCT Error Recovery Control command
SATA Phy Event Counters (GP Log 0x11) not supported
------------------------------------------------------------------------------
Master SQL Server Development, Administration, T-SQL, SSAS, SSIS, SSRS
and more. Get SQL Server skills now (including 2012) with LearnDevNow -
200+ hours of step-by-step video tutorials by Microsoft MVPs and experts.
SALE $99.99 this month only - learn more at:
http://p.sf.net/sfu/learnmore_122512
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database