well at least not in the db: 

root@ubuntu6:~# smartctl -t short
/dev/sda
smartctl 5.43 2012-06-30 r3573 [x86_64-linux-3.5.0-25-generic]
(local build)
Copyright (C) 2002-12 by Bruce Allen,
http://smartmontools.sourceforge.net

=== START OF OFFLINE IMMEDIATE AND
SELF-TEST SECTION ===
Sending command: "Execute SMART Short self-test
routine immediately in off-line mode".
Drive command "Execute SMART
Short self-test routine immediately in off-line mode"
successful.
Testing has begun.
Please wait 1 minutes for test to
complete.
Test will complete after Fri Feb 22 13:44:34 2013

Use
smartctl -X to abort test.
root@ubuntu6:~# smartctl -x /dev/sda
smartctl
5.43 2012-06-30 r3573 [x86_64-linux-3.5.0-25-generic] (local
build)
Copyright (C) 2002-12 by Bruce Allen,
http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION
===
Device Model: TS128GSSD320
Serial Number: A291041947346619003A
LU
WWN Device Id: 0 0232d0 000000000
Firmware Version: 5.0.4
User Capacity:
128,035,676,160 bytes [128 GB]
Sector Size: 512 bytes
logical/physical
Device is: Not in smartctl database [for details use:
-P showall]
ATA Version is: 8
ATA Standard is: ACS-2 revision 3
Local
Time is: Fri Feb 22 13:47:34 2013 CET
SMART support is: Available -
device has SMART capability.
SMART support is: Enabled
AAM feature is:
Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is:
Disabled
Write cache is: Enabled
ATA Security is: Disabled, NOT FROZEN
[SEC1]

=== START OF READ SMART DATA SECTION ===
SMART overall-health
self-assessment test result: PASSED

General SMART Values:
Offline data
collection status: (0x02) Offline data collection activity
 was
completed without error.
 Auto Offline Data Collection:
Disabled.
Self-test execution status: ( 0) The previous self-test
routine completed
 without error or no self-test has ever 
 been
run.
Total time to complete Offline 
data collection: ( 0)
seconds.
Offline data collection
capabilities: (0x7b) SMART execute
Offline immediate.
 Auto Offline data collection on/off support.

Suspend Offline collection upon new
 command.
 Offline surface scan
supported.
 Self-test supported.
 Conveyance Self-test supported.

Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART
data before entering
 power-saving mode.
 Supports SMART auto save
timer.
Error logging capability: (0x01) Error logging supported.

General Purpose Logging supported.
Short self-test routine 
recommended
polling time: ( 1) minutes.
Extended self-test routine
recommended
polling time: ( 48) minutes.
Conveyance self-test routine
recommended
polling time: ( 2) minutes.
SCT capabilities: (0x0021) SCT Status
supported.
 SCT Data Table supported.

SMART Attributes Data Structure
revision number: 10
Vendor Specific SMART Attributes with
Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE

1 Raw_Read_Error_Rate POSR-- 100 100 050 - 3269245
 5
Reallocated_Sector_Ct PO--CK 100 100 003 - 0
 9 Power_On_Hours -O--CK
100 100 000 - 591 (78 220 0)
 12 Power_Cycle_Count -O--CK 100 100 000 -
2
171 Unknown_Attribute -O--CK 000 000 000 - 0
172 Unknown_Attribute
-O--CK 000 000 000 - 0
174 Unknown_Attribute ----CK 000 000 000 - 90
177
Wear_Leveling_Count ------ 000 000 000 - 2
181 Program_Fail_Cnt_Total
-O--CK 000 000 000 - 0
182 Erase_Fail_Count_Total -O--CK 000 000 000 -
0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
194 Temperature_Celsius
-O---K 031 056 000 - 31 (Min/Max 13/56)
195 Hardware_ECC_Recovered
--SRC- 120 120 000 - 3269245
196 Reallocated_Event_Count PO--CK 100 100
003 - 0
201 Soft_Read_Error_Rate --SRC- 120 120 000 - 3269245
204
Soft_ECC_Correction --SRC- 120 120 000 - 3269245
230 Head_Amplitude
PO--C- 100 100 000 - 100
231 Temperature_Celsius PO--C- 100 100 010 -
0
233 Media_Wearout_Indicator ------ 000 000 000 - 797
234
Unknown_Attribute -O--CK 000 000 000 - 1065
241 Total_LBAs_Written
-O--CK 000 000 000 - 1065
242 Total_LBAs_Read -O--CK 000 000 000 - 884

||||||_ K auto-keep
 |||||__ C event count
 ||||___ R error rate

|||____ S speed/performance
 ||_____ O updated online
 |______ P
prefailure warning

General Purpose Log Directory Version 1
SMART Log
Directory Version 1 [multi-sector log support]
GP/S Log at address 0x00
has 1 sectors [Log Directory]
GP Log at address 0x07 has 1 sectors
[Extended self-test log]
SMART Log at address 0x09 has 1 sectors
[Selective self-test log]
GP Log at address 0x10 has 1 sectors [NCQ
Command Error log]
GP/S Log at address 0x11 has 1 sectors [SATA Phy
Event Counters]
GP/S Log at address 0x80 has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x81 has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x82 has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x83 has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x84 has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x85 has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x86 has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x87 has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x88 has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x89 has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x8a has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x8b has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x8c has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x8d has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x8e has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x8f has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x90 has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x91 has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x92 has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x93 has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x94 has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x95 has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x96 has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x97 has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x98 has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x99 has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x9a has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x9b has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x9c has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x9d has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x9e has 16 sectors [Host vendor
specific log]
GP/S Log at address 0x9f has 16 sectors [Host vendor
specific log]
GP/S Log at address 0xb7 has 16 sectors [Device vendor
specific log]
GP/S Log at address 0xe0 has 1 sectors [SCT
Command/Status]
GP/S Log at address 0xe1 has 1 sectors [SCT Data
Transfer]

SMART Extended Comprehensive Error Log (GP Log 0x03) not
supported
SMART Error Log not supported
SMART Extended Self-test Log
Version: 1 (1 sectors)
No self-tests have been logged. [To run
self-tests, use: smartctl -t]

SMART Selective self-test log data
structure revision number 1
 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
 1
0 0 Not_testing
 2 0 0 Not_testing
 3 0 0 Not_testing
 4 0 0
Not_testing
 5 0 0 Not_testing
Selective self-test flags (0x0):
 After
scanning selected spans, do NOT read-scan remainder of disk.
If
Selective self-test is pending on power-up, resume after 0 minute
delay.

Error unknown SCT Temperature History Format Version (10),
should be 2.
Warning: device does not support SCT Error Recovery Control
command
SATA Phy Event Counters (GP Log 0x11)
ID Size Value
Description
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR
response for device-to-host data FIS
0x0004 2 0 R_ERR response for
host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host
non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data
FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 10
Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 8 Device-to-host
register FISes sent due to a COMRESET
0x000f 2 0 R_ERR response for
host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for
host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for
host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for
host-to-device non-data FIS, non-CRC
0x0002 2 0 R_ERR response for data
FIS
0x0005 2 0 R_ERR response for non-data FIS
0x000b 2 0 CRC errors
within host-to-device FIS
0x000d 2 0 Non-CRC errors within
host-to-device FIS

Best regards and keep up with the very good work,


-- 
Siniša Bandin
Novi Sad, Serbia

 
------------------------------------------------------------------------------
Everyone hates slow websites. So do we.
Make your web apps faster with AppDynamics
Download AppDynamics Lite for free today:
http://p.sf.net/sfu/appdyn_d2d_feb
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to