Please find attached a submission for the disk TOSHIBA MK1246GSX
smartctl 6.0 2012-10-10 r3643 [i686-w64-mingw32-vista-sp2] (sf-6.0-1)
Copyright (C) 2002-12, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     TOSHIBA MK1246GSX
Serial Number:    488LT9YDT
LU WWN Device Id: 5 000039 0f1a025c6
Firmware Version: LB213M
User Capacity:    120,034,123,776 bytes [120 GB]
Sector Size:      512 bytes logical/physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ATA8-ACS (minor revision not indicated)
SATA Version is:  SATA 2.6, 1.5 Gb/s
Local Time is:    Fri Mar 15 16:52:41 2013 GMTST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                (  120) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  59) minutes.
SCT capabilities:              (0x0039) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000b   100   100   050    Pre-fail  Always       
-       0
  2 Throughput_Performance  0x0005   100   100   050    Pre-fail  Offline      
-       0
  3 Spin_Up_Time            0x0027   100   100   001    Pre-fail  Always       
-       1067
  4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       
-       1958
  5 Reallocated_Sector_Ct   0x0033   100   100   050    Pre-fail  Always       
-       2
  7 Seek_Error_Rate         0x000b   100   100   050    Pre-fail  Always       
-       0
  8 Seek_Time_Performance   0x0005   100   100   050    Pre-fail  Offline      
-       0
  9 Power_On_Hours          0x0032   095   095   000    Old_age   Always       
-       2192
 10 Spin_Retry_Count        0x0033   139   100   030    Pre-fail  Always       
-       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       1927
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       
-       27
193 Load_Cycle_Count        0x0032   095   095   000    Old_age   Always       
-       59632
194 Temperature_Celsius     0x0022   100   100   000    Old_age   Always       
-       30 (Min/Max 11/51)
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       
-       2
197 Current_Pending_Sector  0x0032   100   100   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0030   100   100   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x0032   200   200   000    Old_age   Always       
-       1
220 Disk_Shift              0x0002   100   100   000    Old_age   Always       
-       75
222 Loaded_Hours            0x0032   097   097   000    Old_age   Always       
-       1474
223 Load_Retry_Count        0x0032   100   100   000    Old_age   Always       
-       0
224 Load_Friction           0x0022   100   100   000    Old_age   Always       
-       0
226 Load-in_Time            0x0026   100   100   000    Old_age   Always       
-       335
240 Head_Flying_Hours       0x0001   100   100   001    Pre-fail  Offline      
-       0

SMART Error Log Version: 1
ATA Error Count: 1
        CR = Command Register [HEX]
        FR = Features Register [HEX]
        SC = Sector Count Register [HEX]
        SN = Sector Number Register [HEX]
        CL = Cylinder Low Register [HEX]
        CH = Cylinder High Register [HEX]
        DH = Device/Head Register [HEX]
        DC = Device Command Register [HEX]
        ER = Error register [HEX]
        ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 1 occurred at disk power-on lifetime: 1902 hours (79 days + 6 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 01 c2 60 a7 e0  Error: ICRC, ABRT at LBA = 0x00a760c2 = 10969282

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  ca 00 08 bb 60 a7 e0 00      01:07:14.043  WRITE DMA
  ca 00 08 b3 60 a7 e0 00      01:07:14.043  WRITE DMA
  ca 00 08 ab 60 a7 e0 00      01:07:14.043  WRITE DMA
  ca 00 08 a3 60 a7 e0 00      01:07:14.043  WRITE DMA
  ca 00 08 9b 60 a7 e0 00      01:07:14.042  WRITE DMA

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%      2115         -
# 2  Short offline       Completed without error       00%      2030         -
# 3  Short offline       Completed without error       00%      1984         -
# 4  Short offline       Completed without error       00%      1490         -
# 5  Short offline       Completed without error       00%      1478         -
# 6  Short offline       Completed without error       00%      1441         -
# 7  Short offline       Completed without error       00%      1332         -
# 8  Short offline       Completed without error       00%         0         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
Everyone hates slow websites. So do we.
Make your web apps faster with AppDynamics
Download AppDynamics Lite for free today:
http://p.sf.net/sfu/appdyn_d2d_mar
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to