Please add the Transcend PSD330 64 GB to the database.

-- 
Kyle Sebion
Developer
Digital Forces Corp

*Contact Information*
Support 24/7/364: *630-978-2000 X 1*. Quickest response. Rings multiple
people.
Direct: 630-299-4971. Follows me.
Office 7 am-5 pm: 630-978-2000 x 804. One business day.
Email: h...@digitalforces.com. Fastest email response one business day.
Texting: 630-447-0804.  Texting is not dependable.
smartctl 6.1 2013-03-16 r3800 [i686-w64-mingw32-xp-sp3] (sf-6.1-1)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     TS64GPSD320
Serial Number:    A58378740151FC000109
Firmware Version: 20120517
User Capacity:    64,022,904,832 bytes [64.0 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ACS-2 (minor revision not indicated)
Local Time is:    Wed May 08 19:41:12 2013 CDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM feature is:   Unavailable
Rd look-ahead is: Unavailable
Write cache is:   Enabled
ATA Security is:  Disabled, frozen [SEC2]

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Total time to complete Offline 
data collection:                (    0) seconds.
Offline data collection
capabilities:                    (0x00)         Offline data collection not 
supported.
SMART capabilities:            (0x0000) Automatic saving of SMART data          
                        is not implemented.
Error logging capability:        (0x00) Error logging supported.
                                        No General Purpose Logging support.

SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     ------   100   100   000    -    0
  5 Reallocated_Sector_Ct   ------   100   100   000    -    0
 12 Power_Cycle_Count       ------   100   100   000    -    21
161 Unknown_Attribute       ------   100   100   000    -    131
162 Unknown_Attribute       ------   100   100   000    -    65
163 Unknown_Attribute       ------   100   100   000    -    16
164 Unknown_Attribute       ------   100   100   000    -    182687
165 Unknown_Attribute       ------   100   100   000    -    131
166 Unknown_Attribute       ------   100   100   000    -    65
167 Unknown_Attribute       ------   100   100   000    -    89
192 Power-Off_Retract_Count ------   100   100   000    -    0
199 UDMA_CRC_Error_Count    ------   100   100   000    -    2
241 Total_LBAs_Written      ------   100   100   000    -    4955
242 Total_LBAs_Read         ------   100   100   000    -    1363
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

ATA_READ_LOG_EXT (addr=0x00:0x00, page=0, n=1) failed: Input/output error
Read GP Log Directory failed

SMART Log Directory Version 1 [multi-sector log support]
Address    Access  R/W   Size  Description
0x00           SL  R/O      1  Log Directory
0x01           SL  R/O      1  Summary SMART error log
0x06           SL  R/O      1  SMART self-test log
0x80-0x8f      SL  R/W     16  Host vendor specific log

SMART Extended Comprehensive Error Log (GP Log 0x03) not supported

SMART Error Log Version: 1
No Errors Logged

SMART Extended Self-test Log (GP Log 0x07) not supported

SMART Self-test log structure revision number 256
Warning: ATA Specification requires self-test log structure revision number = 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


Selective Self-tests/Logging not supported

SCT Commands not supported

Device Statistics (GP Log 0x04) not supported

SATA Phy Event Counters (GP Log 0x11) not supported

------------------------------------------------------------------------------
Learn Graph Databases - Download FREE O'Reilly Book
"Graph Databases" is the definitive new guide to graph databases and 
their applications. This 200-page book is written by three acclaimed 
leaders in the field. The early access version is available now. 
Download your free book today! http://p.sf.net/sfu/neotech_d2d_may
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to