Hi!

I have 2.5'' usb hdd «Seagate Backup Plus Portable STBU1000200 1TB»:

smartctl -a /dev/sdc
smartctl 5.43 2012-06-30 r3573 [x86_64-linux-3.8.0-21-generic] (local build)
Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net

/dev/sdc: Unknown USB bridge [0x0bc2:0xa013 (0x100)]
Smartctl: please specify device type with the -d option.

Use smartctl -h to get a usage summary


Please add it to «Supported Devices» 
http://sourceforge.net/apps/trac/smartmontools/wiki/Supported_USB-Devices — 
it works with «-d sat» option:


smartctl -d sat -a /dev/sdc
smartctl 5.43 2012-06-30 r3573 [x86_64-linux-3.8.0-21-generic] (local build)
Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Momentus SpinPoint M8 (AFT)
Device Model:     ST1000LM024 HN-M101MBB
Serial Number:    S2TPJ9CD134550
LU WWN Device Id: 5 0004cf 2098cd0a0
Firmware Version: 2AR10001
User Capacity:    1 000 204 886 016 bytes [1,00 TB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 6
Local Time is:    Tue May 28 22:25:09 2013 YEKT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine 
completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                (12540) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        ( 209) minutes.
SCT capabilities:              (0x003f) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE 
UPDATED  WHEN_FAILED RAW_VALUE
   1 Raw_Read_Error_Rate     0x002f   100   100   051    Pre-fail 
Always       -       0
   2 Throughput_Performance  0x0026   252   252   000    Old_age 
Always       -       0
   3 Spin_Up_Time            0x0023   086   086   025    Pre-fail 
Always       -       4460
   4 Start_Stop_Count        0x0032   100   100   000    Old_age 
Always       -       7
   5 Reallocated_Sector_Ct   0x0033   252   252   010    Pre-fail 
Always       -       0
   7 Seek_Error_Rate         0x002e   252   252   051    Old_age 
Always       -       0
   8 Seek_Time_Performance   0x0024   252   252   015    Old_age 
Offline      -       0
   9 Power_On_Hours          0x0032   100   100   000    Old_age 
Always       -       3
  10 Spin_Retry_Count        0x0032   252   252   051    Old_age 
Always       -       0
  11 Calibration_Retry_Count 0x0032   252   252   000    Old_age 
Always       -       0
  12 Power_Cycle_Count       0x0032   100   100   000    Old_age 
Always       -       7
191 G-Sense_Error_Rate      0x0022   252   252   000    Old_age   Always 
       -       0
192 Power-Off_Retract_Count 0x0022   252   252   000    Old_age   Always 
       -       0
194 Temperature_Celsius     0x0002   064   064   000    Old_age   Always 
       -       36 (Min/Max 25/36)
195 Hardware_ECC_Recovered  0x003a   100   100   000    Old_age   Always 
       -       0
196 Reallocated_Event_Count 0x0032   252   252   000    Old_age   Always 
       -       0
197 Current_Pending_Sector  0x0032   252   252   000    Old_age   Always 
       -       0
198 Offline_Uncorrectable   0x0030   252   252   000    Old_age 
Offline      -       0
199 UDMA_CRC_Error_Count    0x0036   200   200   000    Old_age   Always 
       -       0
200 Multi_Zone_Error_Rate   0x002a   100   100   000    Old_age   Always 
       -       0
223 Load_Retry_Count        0x0032   252   252   000    Old_age   Always 
       -       0
225 Load_Cycle_Count        0x0032   100   100   000    Old_age   Always 
       -       43

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


Note: selective self-test log revision number (0) not 1 implies that no 
selective self-test has ever been run
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever 
been run
  SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
     1        0        0  Completed [00% left] (0-65535)
     2        0        0  Not_testing
     3        0        0  Not_testing
     4        0        0  Not_testing
     5        0        0  Not_testing
Selective self-test flags (0x0):
   After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.


-- 
Yours respectfully,
Aleksey Vazhnov
jabber: vazh...@jabber.ru, vazh...@jabber.org

------------------------------------------------------------------------------
Try New Relic Now & We'll Send You this Cool Shirt
New Relic is the only SaaS-based application performance monitoring service 
that delivers powerful full stack analytics. Optimize and monitor your
browser, app, & servers with just a few lines of code. Try New Relic
and get this awesome Nerd Life shirt! http://p.sf.net/sfu/newrelic_d2d_may
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to