Hi! I have 2.5'' usb hdd «Seagate Backup Plus Portable STBU1000200 1TB»:
smartctl -a /dev/sdc smartctl 5.43 2012-06-30 r3573 [x86_64-linux-3.8.0-21-generic] (local build) Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net /dev/sdc: Unknown USB bridge [0x0bc2:0xa013 (0x100)] Smartctl: please specify device type with the -d option. Use smartctl -h to get a usage summary Please add it to «Supported Devices» http://sourceforge.net/apps/trac/smartmontools/wiki/Supported_USB-Devices — it works with «-d sat» option: smartctl -d sat -a /dev/sdc smartctl 5.43 2012-06-30 r3573 [x86_64-linux-3.8.0-21-generic] (local build) Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Model Family: Seagate Momentus SpinPoint M8 (AFT) Device Model: ST1000LM024 HN-M101MBB Serial Number: S2TPJ9CD134550 LU WWN Device Id: 5 0004cf 2098cd0a0 Firmware Version: 2AR10001 User Capacity: 1 000 204 886 016 bytes [1,00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Device is: In smartctl database [for details use: -P show] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 6 Local Time is: Tue May 28 22:25:09 2013 YEKT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (12540) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 209) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 100 100 051 Pre-fail Always - 0 2 Throughput_Performance 0x0026 252 252 000 Old_age Always - 0 3 Spin_Up_Time 0x0023 086 086 025 Pre-fail Always - 4460 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 7 5 Reallocated_Sector_Ct 0x0033 252 252 010 Pre-fail Always - 0 7 Seek_Error_Rate 0x002e 252 252 051 Old_age Always - 0 8 Seek_Time_Performance 0x0024 252 252 015 Old_age Offline - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 3 10 Spin_Retry_Count 0x0032 252 252 051 Old_age Always - 0 11 Calibration_Retry_Count 0x0032 252 252 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 7 191 G-Sense_Error_Rate 0x0022 252 252 000 Old_age Always - 0 192 Power-Off_Retract_Count 0x0022 252 252 000 Old_age Always - 0 194 Temperature_Celsius 0x0002 064 064 000 Old_age Always - 36 (Min/Max 25/36) 195 Hardware_ECC_Recovered 0x003a 100 100 000 Old_age Always - 0 196 Reallocated_Event_Count 0x0032 252 252 000 Old_age Always - 0 197 Current_Pending_Sector 0x0032 252 252 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 252 252 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0036 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x002a 100 100 000 Old_age Always - 0 223 Load_Retry_Count 0x0032 252 252 000 Old_age Always - 0 225 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 43 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] Note: selective self-test log revision number (0) not 1 implies that no selective self-test has ever been run SMART Selective self-test log data structure revision number 0 Note: revision number not 1 implies that no selective self-test has ever been run SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Completed [00% left] (0-65535) 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. -- Yours respectfully, Aleksey Vazhnov jabber: vazh...@jabber.ru, vazh...@jabber.org ------------------------------------------------------------------------------ Try New Relic Now & We'll Send You this Cool Shirt New Relic is the only SaaS-based application performance monitoring service that delivers powerful full stack analytics. Optimize and monitor your browser, app, & servers with just a few lines of code. Try New Relic and get this awesome Nerd Life shirt! http://p.sf.net/sfu/newrelic_d2d_may _______________________________________________ Smartmontools-database mailing list Smartmontools-database@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/smartmontools-database